Hitachi FL.NET User Manual page 120

Option for s10v
Hide thumbs Also See for FL.NET:
Table of Contents

Advertisement

[Parameters]
padr
Struct reqs_p {
long node ;
unsigned short *Erradr ;
} ;
Be sure to specify an even-numbered address in padr.
Parameter
Message transmission service
number
Remote node number
Error code storage address
(*) For the relationship between real address on LPU (memory address) and symbol
name such as XW000, see "Table 2-5 Virtual Address Spare and Symbol
Names." "Memory address" in table is the address to be specified.
[Return code] (for C mode handler only)
0 (0x00000000): Normal termination
-1 (0xFFFFFFFF): Parameter abnormality exists or the handler is busy processing another
-2 (0xFFFFFFFE): Specifies real address (0x01000000 to 0xFFFFFFFE) on CMU at error
[Function]
A stop request will be issued to a remote node.
The FL.NET module does not support the server feature for a stop directive. If a
stop request is issued to the FL.NET module, it returns a response to indicate
that it does not support the stop directive.
: Input parameter storage starting address
: Remote node number (1 to 254)
: Error code storage address
7 (only when a mathematical/logical function
is used)
1 to 254
Specify a real address (even-numbered
address) on the LPU. (*)
message. Error code is stored in area which specified error code storage
address. For content and measure of error code, see "Table 7-3 List of
Detectable Codes."
code storage address. Please review the specified address.
NOTICE
Input range
5-65
5 USER GUIDE