Update USB Module Software
1. Remove shroud. See Remove Shroud.
2. Use software token (206), shown on page 33. See
Graco Control Architecture
manual for instructions.
NOTE: Upgrade all modules in the system to the
software version on the token, even if you are replacing
only one or two modules. Different software versions
may not be compatible.
All data in the module may be reset to factory default
settings. Record all settings and user preferences
before the upgrade, for ease of restoring them following
the upgrade.
The latest software version for each system can be
found at Tech Support at www.graco.com.
313289W
Module Programming
Replace USB Module
1. Remove shroud. See Remove Shroud.
2. Disconnect power.
3. Remove four nuts (4); leave two nuts on left side of
panel tight. Open front panel of control box (11).
4. Disconnect CAN cables and USB cable from USB
module (219).
5. Remove two mounting screws from USB module
and remove module from base.
219
4
11
6. Follow steps in reverse order to install new USB
module.
7. Load software. See Update USB Module
Software.