7. Remove front display panel (204d) and gasket
(204g).
Display Cable
204g
204c
8. Discard old display assembly.
9. Place new front display panel (204d) and gasket
(204g) on front panel of control box (11).
NOTE: To ease installation process use clear tape
to hold front display panel in place.
10. Carefully connect display cables and key switch
cable to new circuit board.
11. Install new rear display panel (204c) and secure
with four screws (204b). Ensure key switch cable
protrudes from opening in top of display module.
12. Install access cover and screws. Apply warning
label to access cover.
13. Reconnect CAN cable to display module.
14. Reconnect power.
15. Load software. See Upgrade Software, 33.
16. Replace shroud.
17. Configure system settings as they were set on old
display. See your XM sprayer operation manual for
instructions.
313289W
239
204d
204b
Replace Front Panel
See Replace Display, page 34, for instructions
Wall Power Supply Control Components
Replace Power Supply Module
1. Remove shroud. See Remove Shroud.
2. Disconnect main power.
3. Remove four nuts (4); leave two nuts on left side of
panel tight. Open front panel of control box (11).
4. Disconnect incoming power cable connections to
power supply module and ground lead (260) from
control box.
5. Disconnect power supply cable (272) from FCM
(218). See Fluid Control Assembly on page 40.
6. Remove four screws (273) holding power supply
module (270) bracket in place.
273
7. Remove and replace power supply module (270).
8. Follow steps in reverse order to install new power
supply module.
Repair
272
270
260
35