20:1 KINGt CARBON STEEL
Cart–Mounted Zinc Spray
Package
Part No. 231131, Series C
2000 psi (14 MPa, 138 bar) Maximum Fluid Working Pressure
100 psi (0.7 MPa, 7 bar) Maximum Air Input Pressure
Read warnings and instructions.
See page 2 for Table of Contents.
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Copyright 2002, Graco Inc. is registered to I.S. EN ISO 9001
308081L
TI1605A

Advertisement

loading

Summary of Contents for Graco 20:1 KING 231131

  • Page 1 100 psi (0.7 MPa, 7 bar) Maximum Air Input Pressure Read warnings and instructions. See page 2 for Table of Contents. TI1605A GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441 Copyright 2002, Graco Inc. is registered to I.S. EN ISO 9001...
  • Page 2 D This equipment is for professional use only. D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor. D Do not alter or modify this equipment.
  • Page 3 Do not repair high pressure couplings; you must replace the entire hose. D Use only Graco approved hoses. Do not remove the spring guard that is used to help protect the hose from rupture caused by kinks or bends near the couplings.
  • Page 4 WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. D Ground the equipment and the object being sprayed. Refer to Grounding on page 6. D If there is any static sparking or you feel an electric shock while using this equipment, stop spray- ing immediately.
  • Page 5 60 cycles per minute. Ensure that you have an adequate compressed air supply. NOTE: Always use Genuine Graco Parts and Acces- sories, available from your Graco distributor. Refer to Refer to Fig. 2. Bring a compressed air supply line (A) the Product Data Sheet for your pump, Form No.
  • Page 6 Setup Grounding 2. Air and fluid hoses: use only electrically conductive hoses. WARNING 3. Air compressor: follow manufacturer’s recommen- FIRE AND EXPLOSION HAZARD dations. Before operating the pump, ground the system as explained below. Also read the section FIRE OR EXPLOSION HAZ- 4.
  • Page 7 Setup D The red-handled bleed-type master air valve (F) Supplied Components is required in your system to relieve air trapped Refer to Fig. 2. between it and the air motor when the valve is closed (see the WARNING above). Be sure the WARNING bleed valve is easily accessible from the pump, and is located downstream from the air filter/regulator...
  • Page 8 Setup SUPPLIED COMPONENTS COMPONENTS YOU MUST SUPPLY Pump Electrically Conductive Air Supply Hose Cart Bleed-Type Master Air Valve Fluid Return Line Valve (for accessories) Fluid Return Line Air Line Moisture Trap and Drain Valve 10 Fluid Return Tube Grounded 5 Gallon (19 Liter) Pail 12 Electrically Conductive Fluid Supply Hose 13 Coupling 14 Electrically Conductive Fluid Whip Hose...
  • Page 9 Operation Pressure Relief Procedure Packing Nut/Wet-Cup Before starting, fill the packing nut (K) 1/3 full with WARNING Graco Throat Seal Liquid (TSL) or compatible solvent. See Fig. 3. INJECTION HAZARD The system pressure must be manually WARNING relieved to prevent the system from starting or spraying accidentally.
  • Page 10 Operation Set the Air and Fluid Pressure CAUTION WARNING To avoid tip-over, the cart must be on a flat and level surface. Failure to follow this caution could result in To reduce the risk of serious injury whenever you injury or equipment damage. are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 9.
  • Page 11 Operation Shutdown and Care of the Pump WARNING WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the To reduce the risk of serious injury whenever you Pressure Relief Procedure on page 9. are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 9.
  • Page 12 Operation Fluid Return Line Valve 24 Suction Hose Red-Handled Bleed-Type Master Fluid Return Line 26 Suction Tube Air Valve (required, for pump) 10 Fluid Return Tube Main Air Line G Air Line Inlet Swivel 12 Electrically Conductive Fluid Supply Hose Bleed-Type Master Air Valve Packing Nut/Wet-Cup 17 Airless Spray Gun...
  • Page 13 Notes 308081...
  • Page 14 Parts Part No. 231131, Series C 20:1 Ratio Kingt Pump with Dura-Flot 2400 Displacement Pump 06363B 308081...
  • Page 15 Parts Part No. 231131, Series C 20:1 Ratio Kingt Pump with Dura-Flot 2400 Displacement Pump Ref. Ref. Part No. Description Qty. Part No. Description Qty. 222832 PUMP, King, 20:1 ratio; 113344 UNION, swivel; See manual 308151 for parts 1/2 npt(m) x 3/4 npsm(f) 244530 CART, portable 222916...
  • Page 16 Technical Data Category Data Maximum fluid working pressure 2000 psi (14 MPa, 138 bar) Maximum air input pressure 100 psi (0.7 MPa, 7 bar) Ratio 20:1 Pump performance data See pump manual 308151 Air consumption data See pump manual 308151 Air inlet size 3/4 npsm(f) Fluid outlet size (at pump)
  • Page 17 Dimensions TI1605A Pump Model Width Across Weight Wheels 231131 53.6 in. (1361 mm) 28.1 in. (714 mm) 30.7 in. (780 mm) 26 in. (660 mm) 295 lb (134 kg) 308081...
  • Page 18 Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.