Cart-mounted zinc spray package

Advertisement

Grounding
WARNING
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below. Also read
the section FIRE OR EXPLOSION HAZ-
ARD on page 4.
1. Pump: use the ground wire and clamp (supplied)
as shown in Fig. 1. Remove the ground screw (Z)
and insert through the eye of the ring terminal at
end of ground wire (Y). Fasten the screw back
onto the pump and tighten securely. Connect the
other end of the wire to a true earth ground.
Z
Fig. 1
6
308081
Setup
2. Air and fluid hoses: use only electrically conductive
3. Air compressor: follow manufacturer's recommen-
4. Spray gun: ground through connection to a prop-
5. Fluid supply container: follow your local code.
6. Object being sprayed: follow your local code.
7. Solvent pails used when flushing: follow your local
Y
8. To maintain grounding continuity when flushing or
TI1052
hoses.
dations.
erly grounded fluid hose and pump.
code. Use only metal pails, which are conductive,
placed on a grounded surface. Do not place the
pail on a nonconductive surface, such as paper or
cardboard, which interrupts the grounding continu-
ity.
relieving pressure, hold a metal part of the spray
gun firmly to the side of a grounded metal pail,
then trigger the gun.