DuraVent DuraSeal DS Installation Instructions Manual page 18

Single wall or double wall al29-4c or 316l special gas vent for category i, ii, iii and iv type l vent low temperature venting system
Hide thumbs Also See for DuraSeal DS:
Table of Contents

Advertisement

II. Assembly steps for the MALE adapter with the flexible liner
Do steps 1.1 to 1.2, and 2.1 to 2.S of the upper side of the FLEX-FLEX
adaptor.
Ill. Assembly steps for the FEMALE adapter with the flexible liner
Do steps 1.1 to 1.2, and 3.1 to 3.S of the lower side of the FLEX-FLEX
adaptor.
Figure 25- DuraSeal Flex Adapter - Elbow in masonry
18
BASIC DuraSeal FLEX LINER INSTALLATION
1- Determine the required location and opening in the masonry chimney.
For a basic DuraSeal Flex installation the opening must be large
enough for the mortar sleeve and Male Flex Adapter and the
DuraSeal Flex to easily pass through. If a Tee application is necessary,
a largerhole may be required.
2- Make sure the DuraSeal Flex is supported at the bottom of the
chimney. Refer to Figure 12 forguiding and support installation in the
masonry chimney.
3- The DuraSeal Flex liner must be installed from the top of the masonry
chimney. To prevent damage, one person should feed the liner through
the chimney and another person should pull the liner from the bottom.
To ease the installation, you can attach a rope to the DuraSeal Flex
liner above the Male Flex Adapter. Doing this will reduce the chance of
breaking the seal between the DuraSeal Flex and the Male Flex
Adapter.
4-The DuraSeal Flex must stay within the masonry chimney; however
the Elbow or other DuraSeal components will extend beyond the
masonry chimney. (Figure 25)
S- It is strongly recommended to use a drain between the Male Flex
Adapter and the appliance (refer to Condensate Drains section).
GUY SUPPORT (GS)