Phase error
Linearity
Position sensitivity
External field
Minimum load
Noise
Gain variation
Operating temperature
i3000s (24 and 36 Flex)
i2000 Flex
Storage temperature
i3000s (24 and 36 Flex)
i2000 Flex
Temperature coefficient:
Operating humidity:
Altitude:
Power supply
Battery life
i3000s (24 and 36 Flex)
i2000 Flex
Low battery
General Characteristics
Output con.
i3000s (24 and 36 Flex)
i2000 Flex
Weight
Fluke-Direct
Page 4
< ±1° (45 Hz to 65 Hz),
±10° (at 20 kHz)
±0.2 % of reading from 10 % to
100 % of range
±2 % of range with cable >25 mm
(1 inch) from the coupling
±1 % of range with cable
>200 mm (8 in) from the head
100 k for specified accuracy
8 mV RMS (0.3 % of range) in
30 A range
2 mV RMS (0.1 % of range) in
300 A and 3000 A
±0.08 %/°C
-20 to +85 °C (-4 °F to +185 °F)
0 to 70 °C (32 °F to +158 °F)
-20 to +85 °C (-4 °F to +185 °F)
0 to 70 °C (32 °F to +158 °F)
± 0.08 % of reading / °C
15 % to 85 % (non condensing)
2000 m
Two AA IEC LR6 alkaline
batteries (all probes)
400 hours typical
200 hours typical
Indicated by a red LED
Coaxial cable with a male
safety BNC connector. BNC to
Banana plug adaptor (supplied)
0.5 m cable with 4 mm safety
plugs
0.19 kg (0.4 lb)