Specifications

Electrical Characteristics
Measurement Range
Frequency Range
Accuracy (@ 25 °C)
Linearity (10 % to 100 % of range)
Temperature Coefficient
Position Sensitivity (with cable >25
mm from the coupling)
External Field (with cable >200 mm
from the head)
Working Voltage (see Safety
Standards)

General Characteristics

Probe and Cable Material
Probe Cable Length
Probe Cable Diameter
Transducer Bend Radius (min)
Output Cable
Output Connector
Operating Temperature Range
Storage Temperature Range
Operating Humidity
Altitude
Degree of ingress protection
Safety Standards
EN/IEC 61010-1:2001
EN/IEC 61010-031:2002+A1:2008
EN/IEC 61010-2-032:2002
Pollution Degree 2
Use of the Probe on uninsulated conductors is limited to 1000 V under CAT III
installations and 600 V under CAT IV installations ac rms or dc and frequencies
below 1 kHz.
Note that the safety rating for the output to ground is limited to 30 V ac rms or dc by
the connector specified.
This Fluke product will be free from defects in material and workmanship for one
year from the date of purchase. This warranty does not cover fuses, disposable
batteries, or damage from accident, neglect, misuse, alteration, contamination, or
abnormal conditions of operation or handling. Resellers are not authorized to extend
any other warranty on Fluke's behalf. To obtain service during the warranty period,
contact your nearest Fluke authorized service center to obtain return authorization
information, then send the product to that Service Center with a description of the
problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH
AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED.
FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR
THEORY. Since some states or countries do not allow the exclusion or limitation of
an implied warranty or of incidental or consequential damages, this limitation of
liability may not apply to you.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.
11/99
-Direct.ca
LIMITED WARRANTY AND LIMITATION OF LIABILITY
Fluke-Direct
20 to 1000 A (with a crest factor ≤3)
40 Hz to 5 kHz
±1 % of reading
±0.2 % of reading
±0.05 % of reading per °C
±2 % of reading
±1 % of reading
1000 V ac rms or dc
Alcryn 2070NC, reinforced insulation,
UL94 V0, Color: RED
24 in. (610 mm)
0.3 in. (8 mm)
1.5 in. (38.1 mm)
2 core screened, double insulated, 3
meters long
LEMO 6 pin male connector
°
-4 to +158
F (-20 to +70
temperature of the conductor under test
shall not exceed 176
°
-40 to 176
F (-40 to +80
15 % to 85 % (non condensing)
max 6562 ft. (2000 m)
IP40 (IEC 60529)
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
°
C) (the
°
°
F /80
C)
°
C)
.ca
1.80

Advertisement