Introduction
The i3000s 24 Flex, i3000s 36 Flex, and i2000 Flex AC Current
Probes (hereafter referred to as "the Probe") are used with
oscilloscopes, digital multimeters, recorders or data loggers. The
i3000s probes can be used to measure AC current up to 3000 A.
The i2000 can be used to measure AC current up to 2000 A. The
flexible measuring head allows current measurements on
conductors that are hard to reach or inaccessible using typical
clamp-on current probes.
The Probes provide a low-voltage (3 V AC for i3000s models,
and 2 V AC for i2000) output that is proportional to the current
being measured. The Probes provide full-scale direct readings for
30 A, 300 A, and 3000 A when using the i3000s models, and 20
A, 200 A, and 2000 A when using the i2000.
Symbols
The following table shows the symbols used on the product
and/or in this manual.
Symbol
~
W
T
-
P
>
PN 2560447
March 2006
©2006 Fluke Corporation. All rights reserved.
i3000s/i2000 Flex
Do not dispose of this product as unsorted municipal
waste. Contact Fluke or a qualified recycler for
disposal.
Important Information. Refer to the manual.
Double/Reinforced insulation.
Do not apply around or remove from the HAZARDOUS
LIVE conductors.
Complies with the relevant European standards.
Conforms to Underwriters' Laboratory, Inc.
AC Current Probe
Instruction Sheet
Description
®

Advertisement

loading

Summary of Contents for Fluke i3000s Flex Series

  • Page 1 Symbol Description Do not dispose of this product as unsorted municipal waste. Contact Fluke or a qualified recycler for disposal. Important Information. Refer to the manual. Double/Reinforced insulation. Do not apply around or remove from the HAZARDOUS LIVE conductors.
  • Page 2: Safety Instructions

    Safety Instructions In this instruction sheet, a Warning identifies conditions and actions that pose hazard(s) to the user. A Caution identifies conditions and actions that may damage the calibrator or the test instruments. WX Warning To avoid electric shock or personal injury: •...
  • Page 3: Specifications

    • Adhere to local and national safety codes. Individual protective equipment must be used to prevent shock and arc blast injury where hazardous live conductors are exposed. • CAT III equipment is designed to protect against the transients in the equipment in fixed equipment installations, such as distribution panels, feeders and short branch circuits, and the lighting systems in...
  • Page 4 ±0.08 %/°C Gain variation Operating temperature -20 to +85 °C (-4 to 185 °F) i3000s (24 and 36 Flex) 0 to 70 °C (32 to 158 °F) i2000 Flex Storage temperature -20 to +85 °C (-4 to 185 °F) i3000s (24 and 36 Flex) 0 to 70 °C (32 to 158 °F) i2000 Flex ±...
  • Page 5 Measuring Head Characteristics Cable length i2000, i3000s 24 Flex 610 mm (24 in), double insulated i3000s 36 Flex 915 mm (36 in), double insulated Cable diameter 14.3 mm (0.562 in) Bend radius 38.1 mm (1.5 in) Output cable 2 m long (78.7 in) Coupling diameter 22.2 mm (0.875 in) Material...
  • Page 6 Operating Instructions Ieb0001.eps Measuring head Measuring head coupling Head output cable Enclosure Power on/Range selector Battery low indicator Power on indicator Output cable Safety BNC connector External power supply input...
  • Page 7 External Power Supply (i3000s Models) An optional Class II external power supply is available from Fluke. The power supply is designed to ensure that the Probe continues to meet its specified safety standards. The usage of a power supply from another vendor is not recommended.
  • Page 8 Measuring Current XWWarning • To avoid electric shock or injury, read Safety Instructions before operating this product • Ensure that the conductor to be tested is de- energized To measure current: Connect the output of the electronics to the input of an oscilloscope or other data recording device.
  • Page 9: Maintenance

    Operation To activate the unit, move the switch from ‘Off’ position to the required measuring range. If the value of current being measured is unknown, select the 3000 A (i3000s models) or 2000 A (i2000) current range and then reduce accordingly. Battery Status Battery status is indicated by an LED on the front of the probe.
  • Page 10: Limited Warranty And Limitation Of Liability

    LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

This manual is also suitable for:

I2000 flexI3000s 24 flexI3000s 36 flex