GE AL-1291 Point ID Installation Manual page 9

Data gathering panel
Table of Contents

Advertisement

Jumpers
Use the two jumpers (Figure 4 on page 7) on the DGP as follows:
TERM (JP1). Fit the JP1 jumper on the DGP if the DGP is the last device on the control panel system
bus.
LRN (JP2). Short the JP2 jumper for two seconds to start learn mode and enable the DGP to
recognize (learn) point ID devices.
Point ID device address settings
The point ID device address settings are directly linked to the zone number the device will have on the DGP
(Table 3). The address numbering starts at 0.
Table 3.
Device addresses and related zone numbers
DGP
Zones
Control panel
1 to 16
DGP 1
17 to 32
DGP 2
33 to 48
DGP 3
49 to 64
DGP 4
65 to 80
DGP 5
81 to 96
DGP 6
97 to 112
DGP 7
113 to 128
The 4I4O point ID devices require eight zone numbers per device. Be sure to take the 8-zone
requirement into account when addressing the 4I4O devices. For example, if a 4I4O device is the first
device you add to point ID DGP 1, it will be address 0 and the next device you add will be address 8.
Point ID address
DGP
None
DGP 8
0 to 15
DGP 9
0 to 15
DGP 10
0 to 15
DGP 11
0 to 15
DGP 12
0 to 15
DGP 13
0 to 15
DGP 14
0 to 15
DGP 15
Zones
Point ID address
129 to 144
0 to 15
145 to 160
0 to 15
161 to 176
0 to 15
177 to 192
0 to 15
193 to 208
0 to 15
209 to 223
0 to 15
225 to 240
0 to 15
241 to 256
0 to 15