Installation

Install the Cable

1. Loosen the captive screws and remove the front
cover from the enclosure.
2. The cable (23) has bare wires at both ends. Thread
the shortest end (4 in. [102 mm]) into the enclosure
through the strain relief bushing (7). See F
3. Connect the cable wires to the left side of the termi-
nal strip (12), as indicated by the label (37). See
F
. 2 and Table 1.
IG
4. Connect the other end of the cable (5 in. [127 mm])
to the appropriate terminal blocks of the EFCM in
the PD2K Dual Panel Control Enclosure. See F
and Table 2.
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
4
. 2.
IG
. 3
IG
Table 1: Terminal Strip Wire Connections
Cable Wire Colors
Black
White
Red
Green
Orange
Blue
White/Black
Red/Black
Green/Black
Orange/Black
Blue/Black
Red/White
37
7
F
. 2. Connect Cable to Terminal Strip
IG
Pin No.
Switch Wires
1
Air Flow Switch 1 +
2
Air Flow Switch 1 -
3
Air Flow Switch 2 +
4
Air Flow Switch 2 -
5
Pressure Switch 1 +
6
Pressure Switch 1 -
7
Pressure Switch 2 +
8
Pressure Switch 2 -
9
Solenoid 1, + (12V), Red
10
Solenoid 1, - (COM), Black
11
Solenoid 2, + (12V), Red
12
Solenoid 2, - (COM), Black