Install The Pressure Switch - Graco 26A231 Instructions - Parts Manual

Air control box kit
Table of Contents

Advertisement

Installation

Install the Pressure Switch

NOTE: The Air Control Module Kit does not include a
pressure switch (PS). The pressure switch is supplied
with the gun flush box kit. Install the pressure switch in
the interface module as follows.
1. Each gun flush box kit includes one pressure switch
(PS). The Air Control module can accommodate 1
or 2 pressure switches. Install the switch(es) in the
left side of the enclosure. See F
1
Pressure switch is part of gun flush box kit;
not included with Air Control Module Kit.
PS#1
1
PS#2
1
F
. 4. Install Pressure Switch (two shown)
IG
6
. 4.
IG
TI14282a
2. Connect the wires from PS#1 to the right side of the
terminal strip (12) pins 5 (+) & 6 (-), as indicated by
the label (38). See F
12
F
. 5. Connect Pressure Switch to Terminal Strip
IG
3. If using a second gun flush box, connect the wires
from PS#2 to the right side of the terminal strip (12)
pins 7 (+) & 8 (-), as indicated by the label (38). See
F
. 5 and Table 1.
IG
. 5 and Table 1.
IG
38
TI14279a
3A4497A