HARVEY C300-30 Operating Instructions Manual page 15

3hp 10" cabinet table saw
Hide thumbs Also See for C300-30:
Table of Contents

Advertisement

5.4.6 Install the switch
The switch is mounted on the lower right side of the
guide tube by using two sets of bolts which are
pre-installed on the guide tube.
Fig. 14
5.4.7 Install the blade
1. Remove the table insert;
2. Rise the arbor all the way up and set the blade
angle at 0º;
3. Remove the arbor nut and arbor flange from the
arbor, slide the saw blade onto the arbor, making
sure the teeth face the front of the saw, then install
the arbor flange and arbor nut onto the blade;
4. Use the included wrenches to tighten the arbor
nut (turn clockwise to tighten), refer to Fig. 15.
Fig. 15
F ig.14
5.4.8 Install the blade guard
1. Slide the knurled knob out (refer to Fig. 16) and
rotate it forward so it engages the upper bracket.
Fig. 16
2. Slide the blade guard spreader all the way down
into the block, then rotate the knurled knob so it
disengages the bracket and the locking pin
engages the hole in the center of the spreader.
3. Fig.17 shows the blade guard.
Fig. 17
Check if the saw blade is tightened before
operating the machine.
Give the spreader an upward tug to verify if it is
locked in place.