Ametek Reichert Tono-Vera Vet Instructions For Use Manual

Ametek Reichert Tono-Vera Vet Instructions For Use Manual

Tonometer

Advertisement

I N S T R U C T I O N S F O R U S E
Tono-Vera
Vet
Tonometer

Advertisement

Table of Contents
loading

Summary of Contents for Ametek Reichert Tono-Vera Vet

  • Page 1 I N S T R U C T I O N S F O R U S E Tono-Vera ™ Tonometer...
  • Page 2 Reichert and Reichert Technologies are registered trademarks of Reichert, Inc. Tono-Vera, Ocu-Dot, ActiView, and ReichertSync are trademarks of Reichert, Inc. AMETEK is a registered trademark of AMETEK, Inc. All other trademarks are properties of their respective owners. The information contained in this document was accurate at time of publication. Specifications subject to change without notice.
  • Page 3: Table Of Contents

    Table of Warnings and Cautions ������������������������������������������������������������������������������������������������������������������������������������������������������������������������4 Contents Symbol Information �����������������������������������������������������������������������������������������������������������������������������������������������������������������������������5 Introduction �������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������6 Unpacking Instructions ......................................7 In the Box�����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������8 Tono-Vera Vet Tonometer Starter Kit - Rechargeable 16309 ........................8 ™ Tono-Vera Vet Tonometer Starter it - AA Battery 16308 ..........................8 Tono-Vera Vet Tonometer Identification ................................
  • Page 4: Warnings And Cautions

    Warnings and Cautions Reichert Technologies (Reichert) is not responsible for the safety and reliability of this instrument when assembly, disassembly, repair or modification is made by unauthorized dealers or persons, or if instrument is not used in accordance with its Instructions for Use. WARNING: An instruction that draws attention to risk of injury or death.
  • Page 5: Symbol Information

    Symbol Information The following symbols appear on the device. Caution Catalog Number Serial Number Date of Manufacture Manufacturer Waste of Electrical and Electronic Equipment Consult Instructions for Use Fragile Contents in Shipping Container—Handle with Care Do not get Shipping Container Wet This Side Up Type BF Applied Part Compliance with relevant EU requirements...
  • Page 6: Introduction

    Manual Measure mode, Tono-Vera Vet takes measurements only when distributor or contact Customer Service directly at: the Manual Measure Button is pressed. Phone: +1-716-686-4500 Reichert Tono-Vera Vet incorporates a Bluetooth module which ® Toll Free (US Only): 888-849-8955 provides wireless communication to transfer data to an EMR system.
  • Page 7: Unpacking Instructions

    Introduction (continued) Carry Case Unpacking Instructions Retain original packaging to use if future transportation is required. Sleeve and Inner Box Open the Outer Shipping Box and remove the Inner Box. Tono-Vera Vet Base Slide the Sleeve off the Inner Box. Tono-Vera Case Shoulder Strap Remove the Carry Case from the Inner Box.
  • Page 8: In The Box

    In the Box Tono-Vera Vet Tonometer Starter Kit - Rechargeable 16309 Tono-Vera Vet Tonometer Starter Kit - AA Battery 16308 Tono-Vera™ Vet Tonometer Tono-Vera™ Vet Li-Ion Wrist Strap Tono-Vera™ Vet Tonometer Tono-Vera™ Vet AA Battery Pack Wrist Strap 16308-800 Rechargeable Battery Pack 13851-096 16308-800 16315...
  • Page 9: Tono-Vera Vet Tonometer Identification

    In the Box (continued) Tono-Vera Vet Tonometer Identification Tono-Vera Vet Probe Chamber Collar Display Tono-Vera Vet Probe Chamber Menu Button Multifunction Buttons Canthus Mark Canthus Mark Manual Measure Button Battery Pack Battery Pack Release Release USB-C Charging Port (Rechargeable Model Only) 16308-101 Rev.
  • Page 10: Instructions For Use

    Instructions for Use Installing the Batteries CAUTION: Use only the battery type specified in technical specification section of this manual. Rechargeable Battery Model Install the country-specific adaptor to the Charging Plug. Insert one end of the USB-C Charging Cable into the Charging Plug, and the other end into the back of the Tono-Vera Vet Charging Base.
  • Page 11: Set Up Base

    Instructions for Use (continued) Set Up Base The Tono-Vera Vet Base features a convenient dispenser for the Ocu-Dot Probes and also includes a recess to hold the empty Probe Tube while taking a measurement. Open the box and fold the flap back along the side. Probe Tube Insert the Ocu-Dot Probe box with the tray into the back of the Base Holder...
  • Page 12: Menu

    Instructions for Use (continued) Menu Menu Last Title Press the Menu Button to access the Menu. Press the left and right Measurement Navigation Buttons to access the different menu screens. Press the Selected Select Button to change the current setting/selection. The highlighted (White) Not Selected option is the active selection.
  • Page 13: Ocu-Dot Probe Installation

    Instructions for Use (continued) Ocu-Dot Probe Installation Pull off the Tono-Vera Vet Protective Probe Chamber Cover from the Tono-Vera Vet Probe Chamber. Take a new Ocu-Dot Probe Tube from the box and remove the cap. Insert the open end of the Ocu-Dot Probe Tube into the Probe Chamber. Rotate Tono-Vera Vet up so the Ocu-Dot Probe can slide into the Probe Chamber.
  • Page 14: Measurement Screen

    Instructions for Use (continued) Measurement Screen ActiView Positioning System Area: The full-color area on screen where the eye is aligned to the device. Battery Indicator: The battery icon indicates the battery level. ActiView Positioning System Area Species: The species selected. Options are Dog, Cat, Horse, or Rabbit. Battery Indicator Alignment Target: The alignment area, consisting of a circular center Species...
  • Page 15: Positioning

    Instructions for Use (continued) Correct Probe Angle Positioning 6 mm (±2mm) To obtain quick, easy, and accurate IOP results, Tono-Vera Vet features the ActiView Positioning System to guide users to proper alignment. 15° The default Measure Mode is ActiView Auto Measure which enables automatic measurements upon correct alignment.
  • Page 16: Aligning

    Instructions for Use (continued) Aligning Probe Angle (±15º) Using the ActiView Positioning System, slowly align Tono-Vera Vet so the device is level with the eye. NOTE: Tono-Vera Vet is able to measure at a probe angle of ±15º, but the Ocu- Dot Probe must remain perpendicular to the eye.
  • Page 17: Measuring

    Instructions for Use (continued) Measuring If Measure Mode is set to ActiView Auto Measure, measurements will be taken automatically when Tono-Vera Vet is aligned correctly. If Measure Mode is set to ActiView Manual Measure or Manual Measure, press the blue Manual Measure Button to measure upon correct alignment. NOTE: The blue Manual Measure Button can be pressed at any time if the operator wishes to override the auto measurement system.
  • Page 18: Understanding Results

    Instructions for Use (continued) Understanding Results High Confidence Final IOP Result Once enough measurements are taken for a high confidence Final IOP Result, the Final IOP Result will be briefly displayed in a large green ring. After, the measurement screen will reappear and the corresponding OD or OS circle will have a green ring around it.
  • Page 19: Data Transfer

    Instructions for Use (continued) Data Transfer NOTE: After Tono-Vera Vet is paired to the PC, the Bluetooth Tono-Vera Vet is capable of transmitting data via Bluetooth® to EMR, using ReichertSync Software. To successfully transmit data, Tono- connection will automatically reconnect when the device is powered ™...
  • Page 20: Tono-Vera Vet Training Aid

    Instructions for Use (continued) Tono-Vera Vet Training Aid The included Training Aid allows users to become familiar with the operation of Tono-Vera Vet. The Training Aid is designed to simulate the experience of aligning the device using the ActiView Positioning System to take measurements.
  • Page 21: Cleaning & Maintenance

    Cleaning and Maintenance Probe Chamber A replacement Probe Chamber is included with the Tono-Vera Replacement Vet so that the device can be used while the Probe Chamber is Replace the Probe Chamber every twelve months or anytime being cleaned. cleaning does not resolve any measuring issues. Cleaning Remove the Probe Chamber.
  • Page 22: Cleaning Tono-Vera Vet

    Replace Tono-Vera Vet batteries when needed. Only replace with new WARNING: Do not spray, pour, or spill liquid onto Tono-Vera Vet, its AA batteries or the Reichert Tono-Vera Vet Lithium-Ion Rechargeable accessories, connectors, switches, or openings in the body. Remove any Battery Pack.
  • Page 23: Troubleshooting

    Troubleshooting The table below provides a guide for troubleshooting some basic Tono-Vera Vet Tonometer operational problems. If a problem persists after using this guide, contact the Reichert Technical Support Group. Contact information is on the last page of this manual. SYMPTOM PROBABLE CAUSE CORRECTION...
  • Page 24 Troubleshooting (continued) SYMPTOM PROBABLE CAUSE CORRECTION ActiView Auto Measure not selected in Measure Mode. Select ActiView Auto Measure in Measure Mode. Manual Measure Button not pressed when Measure Mode is set Press the Manual Measure Button when the device is properly aligned. to either ActiView Manual Measure or Manual Measure mode.
  • Page 25: Specifications

    Specifications PHYSICAL DIMENSIONS ENVIRONMENTAL REQUIREMENTS TONO-VERA VET DISPLAY DIMENSIONS Operational Environment Ambient Temperature range: 10° to 35°C (50° to 95°F) 55°C Size: 19.8 x 6.6 x 3.0 cm Size: 2.8 x 2.8 cm Relative Humidity range: 30 to 90% (7.8 x 2.6 x 1.2 in) (1.1 x 1.1 in) -10°C Atmospheric Pressure range: 80 kPa to 106 kPa (23.6 to 31.3 in.Hg)
  • Page 26 Specifications (continued) Device Regulatory Classification AS/NZS 4268:2017 Insulation Protection: Internally Powered (6 V battery) Radio equipment and systems – Ingress Protection: IPX0 Short range devices – Limits and methods of measurement Applied Part Type: BF Method of compliance per standard above and RSS-Gen Operation Mode: Continuous FCC Compliance Compliance...
  • Page 27: Guidance Tables

    Guidance Tables FCC Bluetooth RF Transmitter Characteristics • Contains FCC ID: WAP3028 • Contains IC: CYBT-423028-02 • Frequency 2402-2480 MHz, Spread Spectrum IC Bluetooth RF Transmitter Characteristics • License: IC: 7922A-3028 • Frequency 2402-2480 MHz, Spread Spectrum MIC Japan Bluetooth RF Transmitter Characteristics •...
  • Page 28 Guidance Tables (continued) Table 201 – Guidance and Manufacturer’s Declaration Electromagnetic Emissions All Medical Electrical Equipment and Medical Electrical Systems Guidance and Manufacturer’s Declaration – Electromagnetic Emissions Tono-Vera Vet is intended for use in the electromagnetic environment specified below. The customer or user of Tono-Vera Vet should ensure that it is used in such an environment. ELECTROMAGNETIC ENVIRONMENT EMISSIONS TEST COMPLIANCE...
  • Page 29 Guidance Tables (continued) Table 202 – Guidance and Manufacturer’s Declaration Electromagnetic Immunity All Medical Electrical Equipment and Medical Electrical Systems Guidance and Manufacturer’s Declaration – Electromagnetic Immunity Tono-Vera Vet is suitable for use in electromagnetic environment specified below. The customer or user of Tono-Vera Vet should ensure that it is used in such an environment. IMMUNITY TEST IEC 60601 TEST LEVEL COMPLIANCE LEVEL...
  • Page 30 Guidance Tables (continued) Table 204 – Guidance and Manufacturer’s Declaration Electromagnetic Immunity Medical Electrical Equipment and Medical Electrical Systems that are NOT Life-supporting Guidance and Manufacturer’s Declaration – Electromagnetic Immunity Tono-Vera Vet is intended for use in the electromagnetic environment specified below. The customer or user of Tono-Vera Vet should ensure that it is used in such an environment. Immunity Test IEC 60601 Test Level Compliance Level...
  • Page 31 Guidance Tables (continued) Table 206 – Recommended Separation Distances between Portable and Mobile RF Communications Equipment for ME Equipment and ME Systems that are NOT Life-supporting� Guidance and Manufacturer’s Declaration - Electromagnetic Immunity Recommended Separation Distances for between Portable and Mobile RF Communications Equipment and Tono-Vera Vet. Tono-Vera Vet is intended for use in the electromagnetic environment in which radiated RF disturbances are controlled.
  • Page 32 Guidance Tables (continued) Table 9 – Guidance and Manufacturer’s Declaration Electromagnetic Immunity Immunity to Proximity Fields from RF Wireless Communications Equipment Guidance and Manufacturer’s Declaration - Electronic Immunity Tono-Vera Vet is intended for use in the electromagnetic environment as specified below related to proximity fields from RF wireless communications equipment. Electromagnetic Immunity Test IEC 60601 Test Level...
  • Page 33: Warranty

    Warranty This product is warranted by Reichert, Inc. against defective material and workmanship under normal use for a period of two years from the date of invoice to the original purchaser. (An authorized dealer shall not be considered an original purchaser.) Under this warranty, Reichert’s sole obligation is to repair or replace the defective part or product at Reichert’s discretion.
  • Page 34 Notes: 16308-101 Rev. A • 34...
  • Page 35 Notes: 16308-101 Rev. A • 35...
  • Page 36 Reichert, Inc� 3362 Walden Ave. Suite 100 Depew, NY 14043 Toll Free (US Only): 888-849-8955 Phone: +1-716-686-4500 Fax: +1-716-686-4555 Email: reichert.information@ametek.com www.reichert.com Authorized European Repair Center AMETEK GmbH Business Unit Reichert Email: info.reichert-de@ametek.com Tel: +49 (89) 315 89 110 Authorized European Representative...

Table of Contents