05-E4B, 05-E4BG SERIES, WSM

[4] CHECK POINTS OF EVERY 100 HOURS

Cleaning Air Cleaner Element
1. Remove the air cleaner element.
2. Use clean dry compressed air on the inside of the element.
Pressure of compressed air must be under 205 kPa
2
(2.1 kgf/cm
, 30 psi).
Keep reasonable distance between the nozzle and the filter.
NOTE
• The air cleaner uses a dry element. Never apply oil to it.
• Do not operate the engine with filter element removed.
• Change the element once a year or every 6th cleaning.
Cleaning Fuel Filter (Element Type Only)
1. Close the fuel valve (3).
2. Remove the retaining ring (6) and remove the filter cup (5), and
rinse the inside with kerosene.
3. Remove the element (4) and dip it in the kerosene to rinse.
4. After cleaning, reassemble the fuel filter, keeping out dust and
dirt.
5. Bleed the fuel system.
IMPORTANT
• If dust and dirt enter the fuel, the fuel injection pump and
injection nozzle will wear quickly. To prevent this, be sure
to clean the fuel filter cup (5) periodically.
(1) Fuel Valve Body
(2) Air Vent Plug
(3) Fuel Valve
Fan Belt Tension
1. Measure the deflection (A), depressing the belt halfway
between the fan drive pulley and alternator pulley at specified
force 98 N (10 kgf, 22 lbf).
2. If the measurement is not within the factory specifications,
loosen the alternator mounting screws and relocate the
alternator to adjust.
Deflection (A)
Factory specification
(A) Deflection
G-12
GENERAL
9Y1210784GEG0012US0
(4) Filter Element
(5) Filter Cup
(6) Retaining Ring
9Y1210784GEG0013US0
7.0 to 9.0 mm
0.28 to 0.35 in.
9Y1210784GEG0014US0
KiSC issued 03, 2019 A