Summary of Contents for Fife CDP-01

  • Page 1 CDP-01 Additional Instruction Manual Recoiler Application With Sensor Selection Using SE-34 Sensor CDP-01 02-11-05 Figure Sheet 1-811-B...
  • Page 2 CDP-01 02-11-05 Figure Sheet 1-811-B...
  • Page 3 These additional instructions explain the special features of the system delivered to the customer. They are intended for being used in conjunction with the CDP-01 Reference Manual. The CDP-01 Reference Manual applies except as noted to the contrary in these instructions.
  • Page 4 CDP-01 02-11-05 Figure Sheet 1-811-B...
  • Page 5: Table Of Contents

    EXPLANATION OF THE SENSOR MODES.................2-5 START UP / POSITION TRANSDUCER CALIBRATION .............2-6 START UP / SENSOR BANDWIDTH TO MANDREL RATIO CALIBRATION .....2-7 START UP / MANDREL DRIVE POLARITY .................2-8 TROUBLESHOOTING FAULT DIAGNOSIS - FAULT RECTIFICATION ..............3-1 CDP-01 02-11-05 Figure Sheet 1-811-B...
  • Page 6 CDP-01 02-11-05 Figure Sheet 1-811-B...
  • Page 7: General Introduction

    A CDP-01-H12 or CDP-01-M12 is required for this application. Software Part Numbers The software part numbers are located on the side of the CDP-01 housing. They include the Matrix Setup no. (MS), State Machine no. (SM) and firmware version ( Dx ).
  • Page 8 CDP-01 02-11-05 Figure Sheet 1-811-B...
  • Page 9: Overview Of Function

    SUPPLEMENTARY OPERATING MANUAL OVERVIEW OF FUNCTION Operator Control Options The CDP-01 signal amplifier can be operated by way of the CDP-01 control panel (internal operation) or via the parallel port (external operation) with a remote control panel or programmable logic controller.
  • Page 10: Input Matrix - External Control

    SUPPLEMENTARY OPERATING MANUAL Input Matrix - External Control Inputs CDP-01 Modes External Lock Automatic with Center Guiding Automatic with Edge L Sensor Automatic with Edge R Sensor Manual Center Mandrel Jog Mandrel Left Jog Mandrel Right L = Low level...
  • Page 11: Explanation Of The Operating Modes

    Press the - or + key to set ‘Left’ or ‘Right’ to manually alter ‘Right’ the position of the drive. JOG MANDREL LEFT / RIGHT Select ‘Jog Mandrel Left’ or ‘Jog Mandrel Right’ via external control to manually alter the position of the mandrel. CDP-01 02-11-05 Figure Sheet 1-811-B...
  • Page 12 The mandrel drive is switched to Automatic. The mandrel now follows the sensor output signal. System gain can be altered, if desired. Guide point shifts are not allowed in this application. Reference: CDP-01 Reference Manual, ‘Basic Settings’ section. EXTERNAL LOCK Set ‘External Lock’ via external control.
  • Page 13: Explanation Of The Sensor Modes

    SPECIAL- Select this sensor mode while in Manual mode to view or calibrate the output of the Mandrel Position Transducer. SPECIAL- Select this sensor mode while in Manual mode to view the Edge 1 output of the SE-34 sensor. CDP-01 02-11-05 Figure Sheet 1-811-B...
  • Page 14: Start Up / Position Transducer Calibration

    The LED bar graph indicates contrast. If the contrast is too low an error message is displayed (left and right outer LEDs flash). Press the Automatic key to store the settings. Press the Manual key to abort the procedure. CDP-01 02-11-05 Figure Sheet 1-811-B...
  • Page 15: Start Up / Sensor Bandwidth To Mandrel Ratio Calibration

    CDP-01. Locate the end of the SE-34 sensor bandwidth by moving the web edge away from the junction box until the sensor begins to scan.
  • Page 16: Start Up / Mandrel Drive Polarity

    If the mandrel moves to either end, press the Manual key and change the Servo Center polarity. Reference: CDP-01 Reference Manual, section “Servo Center Polarity”. If the mandrel oscillates, press the Manual key and change the Servo Center gain.
  • Page 17: Troubleshooting

    SUPPLEMENTARY OPERATING MANUAL TROUBLESHOOTING An incorrect setting on the CDP-01 is often the cause for incorrect or unwanted guiding characteristics. Faults and the procedures for rectifying the faults are described in more detail in the CDP-01 Reference Manual, Chapter ‘Frequent Setting Errors’. Application-specific faults are explained below.