SETUP CONFIGURATION

The configuration jumpers and switches are located
inside the control box. To access them, open the
enclosure by first removing AC power to the control
box, remove the four screws which secure the cover
plate to the bottom plate, and then remove the top.
The circuit board is attached to the top cover.
Before using this setup procedure, the following must
be determined:
1. Line Voltage: 115 or 230 VAC?
2. Type of Measurement: Web width or edge posi-
tion?
3. Jog Direction: Which direction for each of the
push buttons?
4. Units to be Displayed: Inches or millimeters?
5. Display Polarity: Directions corresponding to in-
creasing and decreasing measurements.
REV DATE 11-02-95
FIGURE 1
Refer to Figure 1 for the location of the jumpers and
switches referred to in the following procedure.
1. To configure the Pro-Trac 100 for 115 VAC or
230 VAC operation, install 16 or 18 AWG wire
jumpers on TB1 terminal block (located inside
the control box) as follows:
A. For 115 VAC operation, use one jumper on
B. For 230 VAC operation, use one jumper on
NOTE:
Steps 2 through 5 describe the jumpers and switches
used to configure the operating parameters of the
Pro-Trac 100 control. These jumpers and switches
are located inside the control box.
Unless otherwise specified, the Pro-Trac 100 control
station will be configured at the factory as follows.:
A. Jumper JP1: "Web Width" position. Display
PRO-TRAC 100 CONTROL STATION
SETUP CONFIGURATION
INSTALLATION INSTRUCTIONS
TB1 from pin 4 to pin 5 and another jumper
on TB1 from pin 6 to pin 7.
TB1 from pin 5 to pin 6.
shows "Web Width."
FIG. 1-596
PAGE 1 OF 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PRO-TRAC 100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Fife PRO-TRAC 100

  • Page 1 Refer to Figure 1 for the location of the jumpers and SETUP CONFIGURATION switches referred to in the following procedure. 1. To configure the Pro-Trac 100 for 115 VAC or The configuration jumpers and switches are located 230 VAC operation, install 16 or 18 AWG wire inside the control box.
  • Page 2 D. Tighten all four screws to seat the rubber move the sensor toward the motor end of seals on the enclosure. the positioner, this jumper must be placed in the “B” position. FIG. 1-596 PRO-TRAC 100 CONTROL STATION REV DATE 11-02-95 SETUP CONFIGURATION PAGE 2 OF 2...

Table of Contents