Cleaning The Strainer; Checking The Earth Conductor - STIEBEL ELTRON DHM 3 Installation Manual

Hydraulically controlled mini instantaneous water heaters
Hide thumbs Also See for DHM 3:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 19
Installation
Maintenance
8.2

Cleaning the strainer

You can clean the fitted strainer after removing the cold water
supply pipe.
8.3

Checking the earth conductor

f Check the earth conductor (in Germany e.g. DGUV A3) on the
f
earth conductor contact of the power cable and on the appli-
ance connector.
8.4
Tests in accordance with VDE 0701/0702
Earth conductor check
f Check the earth conductor (in Germany e.g. BGV A3) on the
f
earth conductor contact of the power cable and on the appli-
ance connector.
28
| DHM
Insulation resistance
f If an appliance with a rated heating output of > 3.5 kW does
f
not achieve an insulation resistance of 300 kΩ, we recom-
mend that the insulating properties of the appliance are
checked by conducting a differential current test of the earth
conductor current / leakage current to VDE 0701/0702 (Fig.
C.3b).
8.5
Replacing the power cable for the DHM 6
f If replacing the cable for the DHM 6, use a power cable with
f
4 mm² cross-section
www.stiebel-eltron.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dhm 4Dhm 6Dhm 7220813220814185473 ... Show all

Table of Contents