Summary of Contents for Endress+Hauser iTEMP TMT82
Page 1
Services XA01006T/09/A3/04.16 71320832 Safety Instructions iTEMP TMT82, TMT84, TMT85 ATEX: II 3D: Ex ia IIIC T85 °C...T120 °C Dc II 3D: Ex tc IIIC T85 °C...T105 °C Dc II 3D: Ex tc IIIC T105 °C Dc II 3D: Ex tc IIIC T120 °C Dc II 3G: Ex nA IIC T6...T4 Gc...
Page 2
CE, il costruttore Endress+Hauser, assicura Por la presente declaración y la inclusión de la marca che il prodotto è conforme alle direttive europee CE, el fabricante Endress+Hauser, declara que el vigenti. Prova della conformità è fornita producto cumple con las directivas europeas dall' o sservanza delle direttive, delle norme e dei pertinentes.
Page 3
Europese Pojasnilo glede potrdila o skladnosti EU richtlijnen. De geldende richtlijnen, normen en Proizvajalec Endress+Hauser s to izjavo o skladnosti documenten zijn aangegeven in de in navedbo oznake CE izjavlja, da je ta izdelek skladen conformiteitsverklaring.
TMT82, TMT84, TMT85 XA01006T Sicherheitshin- weise Explosionsgefährdeter Bereich Explosionsgefährdeter Sicherer Bereich Zone 22 oder Zone 2 Bereich Zone 22 oder Zone 2 TMT8x Abgesetzt montierte Sensorkonfiguration Hilfsenergie siehe unten- z. B. RTD oder TC Sensor, stehende Tabelle (einfaches Betriebsmittel) Elektrische Anschlusswerte optional zwei Kanäle...
XA01006T iTEMP TMT82, TMT84, TMT85 • Für den Betrieb des Feldtransmittergehäuses bei einer Umgebungs- temperatur unter –20 °C sind geeignete Leitungen und für diesen Einsatz zugelassene Leitungseinführungen zu verwenden. • Das Gehäuse des Feldtransmitters ist an die Potenzialausgleichslei- tung anzuschließen.
TMT82, TMT84, TMT85 XA01006T Sicherheitshin- Beachten Sie die Sicherheitshinweise (XA00102T/09/ für TMT82 oder XA00069R/09/ für TMT84, TMT85) und Anschlusswerte für die Zünd- weise: Besondere schutzart Eigensicherheit mit der Kennzeichnung: II1G Ex ia IIC T6. Bedingungen Temperaturtabel- Kategorie Schutzart II 3D Ex ia IIIC T85°C…T120°C Dc...
XA01006T iTEMP TMT82, TMT84, TMT85 Schutzart Umgebungstemperatur Temperaturklasse TMT82 Ex nA IIC T6…T4 Gc –40 °C ≤ Ta ≤ +58 °C –40 °C ≤ Ta ≤ +75 °C –40 °C ≤ Ta ≤ +85 °C TMT84, TMT85 Ex nA IIC T6…T4 Gc –40 °C ≤...
TMT82, TMT84, TMT85 XA01006T Safety instructions Hazardous area Hazardous area Non-hazardous area Zone 22 or Zone 2 Zone 22 or Zone 2 TMT8x Remote mount sensor configuration Power supply see table e.g RTD or TC Sensor electrical connection data...
XA01006T iTEMP TMT82, TMT84, TMT85 • When installing, make sure that the housing and cable glands used meet the requirements according to IEC/EN 60079-0 for Group III enclosures. • For ambient temperatures higher than +70 °C, use suitable heat- resisting cables or wires, cable entries and sealing facilities for Ta +5 K above surrounding.
TMT82, TMT84, TMT85 XA01006T Safety Observe the Safety Instructions (XA00102T/09/ for TMT82 or XA00069R/09/ for TMT84/TMT85) and connection values for instructions: intrinsically safe explosion protection with the designation: II1G Ex ia Special IIC T6. Conditions Temperature Category Type of protection...
XA01006T iTEMP TMT82, TMT84, TMT85 Type Type of protection Ambient temperature Temperature class TMT82 Ex nA IIC T6…T4 Gc –40 °C ≤ Ta ≤ +58 °C –40 °C ≤ Ta ≤ +75 °C –40 °C ≤ Ta ≤ +85 °C TMT84, TMT85 Ex nA IIC T6…T4 Gc...
Brochure sur la protection contre les explosions : CP00021Z/11 complémentaire La brochure sur la protection contre les explosions est disponible : Dans la zone de téléchargement sur le site Internet Endress+Hauser : www.endress.com → Documentations → Avancée → Référence de la documentation : CP00021Z Certificats Déclaration CE de conformité...
TMT82, TMT84, TMT85 XA01006T Conseils de sécurité Zone explosible Zone explosible Zone sûre Zone 0, 1, 2 Zone 1, 2 TMT8x Configuration de capteur en montage déporté Energie auxiliaire voir Par ex. thermorésistance ou tableau ci-dessous - thermocouple, (matériel Valeurs de raccordement électrique simple) en option...
XA01006T iTEMP TMT82, TMT84, TMT85 • Lors du montage, veiller à ce que les boîtiers et raccords de câble utilisés soient conformes aux exigences de IEC/EN 60079-0 pour des boîtiers du groupe III. • Pour des températures ambiantes supérieures à +70 °C il convient d' u tiliser des câbles ou fils, des entrées de câble et des joints...
TMT82, TMT84, TMT85 XA01006T Conseils de Tenir compte des conseils de sécurité (XA00102T/09/ pour TMT82 ou XA00069R/09/ pour TMT84, TMT85) et valeurs de raccordement pour sécurité : le mode de protection "Sécurité intrinséque" avec le marquage : II1G Ex Conditions ia IIC T6.
XA01006T iTEMP TMT82, TMT84, TMT85 Type Mode de protection Température ambiante Classe de Température TMT82 Ex nA IIC T6…T4 Gc –40 °C ≤ Ta ≤ +58 °C –40 °C ≤ Ta ≤ +75 °C –40 °C ≤ Ta ≤ +85 °C TMT84, TMT85 Ex nA IIC T6…T4 Gc...