| DCIPS1B-S-00-B6 Power Supply System
2.4.4 Rectifier Module
The Fan-Cooled DCIPS1B-1200 1200W rectifiers are modular power supplies designed
for parallel operation and hot-plug installation in the DCIPS1B Power Systems.
Each rectifier provides extremely reliable DC power in a very high density. The module
incorporates power monitoring through an internal microprocessor, giving up to the
second updates to the system controller and companion rectifiers. This guarantees
tightly controlled load sharing among rectifiers, and provides status and identification
information to the controller.
The rectifiers operate in parallel using active load sharing. They incorporate soft-start
at both the input and the output, which protects against high incoming and outgoing
currents. The output voltage of the rectifier is automatically adjusted to the required
voltage by the controller.
12

Figure 2-2 DCIPS1B-1200

+1 (208) 635-6400 | www.transtector.com

3.1 Safety Warnings and Guidelines

The following warnings and guidelines should be followed by properly trained and authorized
personnel when installing, operating, commissioning or maintaining this equipment.
Neglecting the instructions may be dangerous to personnel and equipment.
3.1.1 System Markings
The following markings are found on the Power System:
Ground Symbol
DC Ground Symbol
Product Label - The product label contains the system part number, model number, system
ratings and safety approvals. The label is located on the left side of top cover.
3.1.2 Safety Recommendations
Any device that uses electricity requires proper guidelines to ensure safety.
The Power System should only be installed or serviced by a qualified personnel.
Always keep tools away from walkways and aisles. Tools present a tripping hazard
in confined areas.
Keep the system area clear and dust-free during and after the installation.
Always know the location of emergency shut-off switches in case of an accident.
Always wear appropriate eye protection and use appropriate tools for working with
high voltage equipment.
Do not perform any action that creates a potential hazard to other people in the
system area.
Never work alone in potentially hazardous conditions.
Always check for possible hazards before beginning work.
Remove watches, rings and jewelry that may present a hazard while working on the
power system.