Download Print this page

WEG CFW100 Series Quick Reference page 5

V3.1x parameters, alarms and faults
Hide thumbs Also See for CFW100 Series:

Advertisement

Available languages

Available languages

Param.
Description
P000
Access to Parameters
P001
Speed Reference
P002
Output Speed (Motor)
P003
Motor Current
P004
DC Link Voltage
P005
Output Frequency (Motor)
P006
Inverter Status
P007
Output Voltage
P009
Motor Torque
P011
Power Factor
P012
DI8 to DI1 Status
(*)
P013
DO3 to DO1 Status
(*)
P014
AO1 Value
(*)
P018
AI1 Value
(*)
P020
Potentiometer Signal Value
P022
FI Value in Hz
P023
Main SW Version
(*)
P024
Accessory SW Version
P027
Accessory Config.
P029
Power HW Configuration
P030
Module Temperature
P037
Motor Overload Ixt
(*)
P038
Encoder Speed
(*)
P039
Encoder Pulses Count
P045
Fan Enabled Time
P047
CONF Status
P048
Present Alarm
P049
Present Fault
P050
Last Fault
P051
Current At Last Fault
P052
DC Link At Last Fault
P053
Frequency At Last Fault
P054
Temperature Last Fault
P060
Second Fault
P070
Third Fault
P080
Last Fault on Fire Mode
P081
Second Fault on Fire Mode
QUICK REFERENCE OF PARAMETERS, ALARMS AND FAULTS
Adjustable Range
0 to 9999
0 to 9999
0 to 9999
0.0 to 10.0 A
0 to 524 V
0.0 to 400.0 Hz
0 = Ready
1 = Run
2 = Undervoltage
3 = Fault
4 = Self-Tuning
5 = Configuration
6 = DC Braking
7 = Reserved
8 = Fire Mode
0 to 240 V
-200.0 to 200.0 %
0.00 to 1.00
0 to FF (hexa)
Bit 0 = DI1
Bit 1 = DI2
Bit 2 = DI3
Bit 3 = DI4
Bit 4 = DI5
Bit 5 = DI6
Bit 6 = DI7
Bit 7 = DI8
0 to 7 (hexa)
Bit 0 = DO1
Bit 1 = DO2
Bit 2 = DO3
0.0 to 100.0 %
-100.0 to 100.0 %
-100.0 to 100.0 %
0 to 3000 Hz
0.00 to 99.99
0.00 to 99.99
0 = Without Accessory
1 = CFW100-HMIR
2 = CFW100-IOAR
3 = CFW100-CCAN
4 = CFW100-CBLT
5 = CFW100-IODR
6 = CFW100-IOADR
7 = CFW100-IOA
8 = CFW100-IOD
9 = Reserved
10 = CFW100-IOP
0 to 999
-200.0 to 200.0 ºC
0.0 to 100.0 %
0 to 270F (hexa)
0 to FFFF (hexa)
0 to FFFF (hexa)
0 to 33
(Table 1.1 on page
23)
0 to 999
0 to 999
0 to 999
0.0 to 10.0 A
0 to 524 V
0.0 to 400.0 Hz
0.0 to 200.0 ºC
0 to 999
0 to 999
0 to 999
0 to 999
Factory Setting
Prop.
1
ro
ro
ro
ro
ro
ro
ro
ro, VVW
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
According to the
ro
Inverter Model
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
CFW100 | 5

Advertisement

loading