Download Print this page

WEG CFW100 Series Quick Reference page 14

V3.1x parameters, alarms and faults
Hide thumbs Also See for CFW100 Series:

Advertisement

Available languages

Available languages

QUICK REFERENCE OF PARAMETERS, ALARMS AND FAULTS
Param.
Description
P312
Serial Protocol
P313
Action for Communic. Error
P314
Serial Watchdog
P316
Serial Interf. Status
P320
Flying Start / Ride-Through
P331
Voltage Ramp for FS and RT
P332
Dead Time
P340
Auto-Reset Time
P352
Fan Control Config.
(*)
P375
NTC Temperature
P397
Control Config
P399
Motor Rated Efficiency
P400
Motor Rated Voltage
P401
Motor Rated Current
P402
Motor Rated Speed
P403
Motor Rated Frequency
P404
Motor Rated Power
P407
Motor Rated Power Factor
P408
Run Self-Tuning
P409
Stator Resistance
P510
SoftPLC Eng. Unit
P511
SoftPLC Indication Form
P580
Fire Mode Config
P582
Fire Mode Auto-reset Adjustable
P588
EOC Maximum Torque
P589
EOC Minimum Voltage
P590
EOC Minimum Frequency
P591
EOC Hysteresis
P613
Main SW Revision
14 | CFW100
Adjustable Range
0 to 1 = Reserved
2 = Modbus RTU Slave
3 to 4 = Reserved
5 = ModBus RTU Master
0 = Inactive
1 = Ramp Stop
2 = General Disable
3 = Go to LOC
4 = LOC Keep Enab.
5 = Cause Fault
0.0 to 999.0 s
0 = Inactive
1 = Active
2 = Watchdog Error
0 = Inactive
1 = Flying Start
2 = FS / RT
3 = Ride-Through
0.2 to 60.0 s
0.1 to 10.0 s
0 to 255 s
0 = OFF
1 = ON
2 = CT
0 to 200 ºC
0 to F (hexa)
Bit 0 = Slip Compens. Regen.
Bit 1 = Reserved
Bit 2 = Is Stabilization
Bit 3 = P297 reduction in A050
50.0 to 99.9 %
0 to 240 V
0.0 to 10.0 A
0 to 24000 rpm
0 to 400 Hz
0 = 0.16 HP (0.12 kW)
1 = 0.25 HP (0.18 kW)
2 = 0.33 HP (0.25 kW)
3 = 0.50 HP (0.37 kW)
4 = 0.75 HP (0.55 kW)
5 = 1.00 HP (0.75 kW)
0.50 to 0.99
0 = No
1 = Yes
0.01 to 99.99
See options in P209
See options in P210
0 = Inactive
1 = Active
2 = Active / P134
3 = Reserved
4 = Active / General Disable
0 = Limited
1 = Unlimited
0 to 85 %
40 to 80 %
12.0 to 400.0 Hz
0 to 30 %
-9999 to 9999
Factory Setting
Prop.
2
cfg
1
0.0 s
cfg
ro
0
cfg
2.0 s
1.0 s
0 s
2
cfg
ro
1
cfg
According to the
cfg, VVW
Inverter Model
220 V
cfg, VVW
1,0 x I
cfg, VVW
nom
1720 rpm
cfg, VVW
60 Hz
cfg, VVW
2
cfg, VVW
According to the
cfg, VVW
Inverter Model
0
cfg, VVW
According to the
cfg, VVW
Inverter Model
0
1
0
cfg
0
cfg
0 %
cfg
40 %
cfg
20.0 Hz
cfg
10 %
cfg
ro

Advertisement

loading