  • Page 1 PIT m4SEU Control and signal devices Operating Manual-1004648-EN-02...
  • Page 2 Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
  • Page 3: Table Of Contents

    5.6.3.3 Evaluation of the Key ID number with advanced communication..........42 PITreader interface ........................Operating mode lock and operating mode preselection ............5.8.1 Operating mode lock......................... 5.8.2 Operating mode preselection....................Installation ..........................General installation guidelines....................Operating Manual PIT m4SEU 1004648-EN-02...
  • Page 4 Status information about the interface for status information ........... 8.7.2 Status information about the signal outputs O1 ... O4 .............. Technical details ........................Safety characteristic data ......................Order reference ........................10.1 Product ............................. 10.2 Accessories ..........................EC declaration of conformity ....................Operating Manual PIT m4SEU 1004648-EN-02...
  • Page 5: Introduction

    Introduction Introduction Validity of documentation This documentation is valid for the product PIT m4SEU. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 6 Introduction INFORMATION This gives advice on applications and provides information on special fea- tures. Operating Manual PIT m4SEU 1004648-EN-02...
  • Page 7: Overview

    Display elements for the operating mode (one display element per operating mode) Safety controller to activate the selected operating mode Higher-level process controller Safety controller (e.g. PNOZ m B0) with "1oon" evaluation 24 V DC Pushbutton PITreader Display elements Fig.: PIT m4SEU in an application (principle) Operating Manual PIT m4SEU 1004648-EN-02...
  • Page 8: Device Features

    Handshake-controlled communica- tion mode [ 33]) - output (see Advanced communication mode [ 34]) Configurable communication mode for downloading the Key ID number – Transmitter-controlled communication mode – Handshake-controlled communication mode – Advanced communication mode Operating Manual PIT m4SEU 1004648-EN-02...
  • Page 9: Device View

    Outputs O1 ... O4 X4 PITreader interface [1] Device name and order number [2] Serial number [3] LEDs [4] DIP switch for configuring the switching behaviour and configuring the communica- tion mode for downloading the Key ID number Operating Manual PIT m4SEU 1004648-EN-02...
  • Page 10 Overview Fig.: Side view Legend [4] DIP switch for configuring the switching behaviour and configuring the communica- tion mode for downloading the Key ID number Operating Manual PIT m4SEU | 10 1004648-EN-02...
  • Page 11: Safety

    Safety Safety Intended use The PIT m4SEU is suitable for machines that can be operated in multiple operating modes with different safety functions and/or work procedures. It enables you to switch between defined operating modes, such as: Set-up mode Manual mode...
  • Page 12: Safety Regulations

    In the event of an error that can lead to the loss of one of the safety functions, the PIT m4SEU switches to a safe state and the operating mode that is currently selected is main- tained. The only way to return from the safe state is to switch the PIT m4SEU off and then on again.
  • Page 13: Warranty And Liability

    In safety-related applications, please comply with the mission time T in the safety-related characteristic data. When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). Operating Manual PIT m4SEU | 13 1004648-EN-02...
  • Page 14: Security

    Perform a risk assessment in accordance with VDI/VDE 2182 or IEC 62443-3-2 and plan the security measures with care. If necessary, seek advice from Pilz Customer Support. The product is not protected against physical manipulation. For this reason, both the product and the authentication system PITreader, including the cable between the two devices, should be installed in a lockable control cabinet.
  • Page 15 Security Company firewall Machine firewall Internet Company network Machine network Product Configuration computer Fig.: Example network topology Operating Manual PIT m4SEU | 15 1004648-EN-02...
  • Page 16: Function Description

    19]), after a restart the unit will start with the last selected operating mode. If OM storage is not configured, the unit always starts with OM1. For this reason you should make sure that OM1 represents the safest operating mode. Operating Manual PIT m4SEU | 16 1004648-EN-02...
  • Page 17 O1 ... O4 Operating mode outputs for connecting external dis- play elements A1, A2 Supply voltage MSO1 ... MSO5 Operating mode interface Interface for displaying the operating mode that is cur- rently selected, consisting of 5 monitored outputs Operating Manual PIT m4SEU | 17 1004648-EN-02...
  • Page 18: Permissions

    SIo0 ... SIo3 Interface for status information Interface for signalling status information, consisting of 4 signal outputs The PIT m4SEU is protected against unauthorised operation. A switch between operating modes must be enabled via a transponder key on the PITreader. Permissions...
  • Page 19: Configuration Of Functions

    Operating mode 4 Configuration of functions The PIT m4SEU has a DIP switch, which you can use to set the required communication mode for downloading the Key ID number and the device's switching behaviour after the transponder key is removed and after the voltage reset The communication modes have different functions.
  • Page 20 It is essential to note that only the DIP switch settings described above will be assessed as valid. With all other DIP switch settings, the device switches to a "Device error" fault condition. Operating Manual PIT m4SEU | 20 1004648-EN-02...
  • Page 21 "1" signal. NOTICE Changing the operating mode to OM1 by removing the transponder key is not a safety-related function. Switching of the operating mode must be val- idated in accordance with the safety requirements. Operating Manual PIT m4SEU | 21 1004648-EN-02...
  • Page 22: Operating Mode Interface

    "0" signal at all outputs on the operating mode interface (see Switchover time t1 [ 58]). If a Pilz safety controller (e.g. PNOZ m1p) is used in conjunction with an "operating mode selector switch" function element, then this requirement is met automatically. Operating Manual PIT m4SEU...
  • Page 23: Interface For Status Information

    Operator action OM2 selected Operator action OM3 selected Operator action OM4 selected Operator action No permission [2] Application error Device error [3] Error Pushbutton operated incorrectly [4] Application error Transponder key removed Operator action Operating Manual PIT m4SEU | 23 1004648-EN-02...
  • Page 24 [5] In configurations with DIP switch settings [5] … [8], with operating mode preselection the switching of operating mode outputs to the preselected operating mode is displayed for 200 ms. This is used as a feedback for the controller. Operating Manual PIT m4SEU | 24 1004648-EN-02...
  • Page 25: Timing Diagrams

    (e.g. Press pushbutton on input I2 for OM2) 4. Operator action: Remove transponder key SIo0 ... SIo3 Pushbutton "2" Key Mode 02 Fig.: Timing diagram for "Select operating mode" with DIP switch setting [D1] (default setting) and [D5] Operating Manual PIT m4SEU | 25 1004648-EN-02...
  • Page 26 SIo0 ... SIo3 as before 8h ... Bh Key Mode Key Service 01 ... 04 Fig.: Timing diagram for "Remove transponder key" with DIP switch setting [D2], [D4], [D6] and [D8] Operating Manual PIT m4SEU | 26 1004648-EN-02...
  • Page 27: Device Error

    The following timing diagrams show how status information is registered at outputs SIo0 ... SIo3, based on the application errors "No permission". Key: Message is displayed constantly Message is displayed briefly (200 ms) Operating mode Operating Manual PIT m4SEU | 27 1004648-EN-02...
  • Page 28 Operating mode selected with a transponder key that does not have permission for the selected operating mode SIo0 ... SIo3 Pushbutton "2" Key mode 01 Fig.: Timing diagram for operating mode selection with insufficient permission for the desired operat- ing mode Operating Manual PIT m4SEU | 28 1004648-EN-02...
  • Page 29: Application Error: "Pushbutton Operated Incorrectly

    The following timing diagrams show how status information is registered at outputs SIo0 ... SIo3, based on the application errors "Pushbutton operated incorrectly". Key: Message is displayed constantly Message is displayed briefly (200 ms) Operating mode Operating Manual PIT m4SEU | 29 1004648-EN-02...
  • Page 30 "Pushbutton operated for too long" with "Key Service" permission SIo0 ... SIo3 SIo0 ... SIo3 Pushbuttons 10 s Pushbutton "1" "1" ... "4" Key Service Key mode 04 Fig.: Timing diagram for "Pushbutton operated for too long" Operating Manual PIT m4SEU | 30 1004648-EN-02...
  • Page 31: Key Id Interface

    Key ID number. The Key ID number consists of two parts: Bit 27 = 24: Key Mode (0 … 15 Bit 23 = 00: Consecutive number (0 … 9999999 Operating Manual PIT m4SEU | 31 1004648-EN-02...
  • Page 32: Communication Mode For Downloading The Key Id Number

    The unique Key ID number for the relevant transponder key is downloaded to the higher- level process controller using a defined protocol, depending on the coded communication mode. The communication mode is coded on the Key ID interface of the PIT m4SEU (jump- ers available/not available).
  • Page 33: Transmitter-Controlled Communication Mode

    Function description 5.6.2.1 Transmitter-controlled communication mode With transmitter-controlled communication mode, the PIT m4SEU (= transmitter) starts the download of the Key ID number. Features of this communication mode: Download of Key ID number starts once the transponder key is inserted...
  • Page 34: Advanced Communication Mode

    Coding: IN n. c. In handshake-controlled communication mode, the PIT m4SEU can be operated in a func- tional variant. In this case the Key ID number of the transponder key is not downloaded to the controller. The controller is only used to evaluate IDsync on the Key ID interface. In this case IDsync is used as a signal output, enabling the controller to recognise whether the transponder key is valid/invalid.
  • Page 35: Evaluation By A Controller

    No transponder key is inserted or the transponder key that is inserted is invalid. "1" signal A valid transponder key is inserted. The PIT m4SEU signals to the controller when the download starts. The signal is present for 100 ms.
  • Page 36 Receive Bit 13 … Bit 00 Download procedure The PIT m4SEU sets the signal at IDsync (control line) to "1" for 100 ms, thereby signalling to the controller that download has started. A rising edge at IDclock (test pulse line) indicates that the data at data lines IDout0 and IDout1 is present and valid and can be read by the controller.
  • Page 37 <IDclock> = 0 Bit Counter = 14 Start Last Bit Timer Last Bit Timer >= 60ms Clear <IDin0> AND <IDin1> Store ID-Number Fig.: Evaluation of the Key ID number via a controller (principle) Operating Manual PIT m4SEU | 37 1004648-EN-02...
  • Page 38: Evaluation Of The Key Id Number With Handshake-Controlled Communication

    End of Key ID Number Transfer (200 ms) IDend After the last falling edge at IDrequest, the PIT m4SEU still has a "1" signal at output IDresponse for 200 ms. In this way, the end of the Key ID number and therefore the end of the download (End of Key ID Number Transfer) is displayed.
  • Page 39 The controller confirms that it has read the requested data bit without error. "0" signal at IDresponse (handshake line): The PIT m4SEU is ready to issue a new data bit at data line IDdata. "0" signal at IDsync (control line): The transponder key was removed.
  • Page 40 Function description Status diagram for handshake-controlled signal download Fig.: Status diagram for handshake-controlled signal download Operating Manual PIT m4SEU | 40 1004648-EN-02...
  • Page 41 Last Bit Control <IDsync> = 0 <IDresponse> = 0 Time Control <t > >= 200ms IDend Bit Counter = 28 Store ID Number Fig.: Evaluation of the Key ID number via a controller (principle) Operating Manual PIT m4SEU | 41 1004648-EN-02...
  • Page 42: Evaluation Of The Key Id Number With Advanced Communication

    → to adopt the preselected operating mode keylock → to disable the change of operating mode Both signals are sent from the controller to the PIT m4SEU. These are standard inputs that do not affect the safety function of the PIT m4SEU.
  • Page 43 MSO1 selected [8h] [Fh] [Ch] MSO2 selected [9h] MSO1 selected [8h] [0h] SIo0 ... SIo3 Output MSO1 MSO2 Fig.: Changing the operating mode after removing the transponder key, with DIP switch settings [D7] Operating Manual PIT m4SEU | 43 1004648-EN-02...
  • Page 44: Operating Mode Preselection

    The interface for status information still displays the same operating mode and confirms the transfer of the preselected operating mode to the selected operating mode with the status information "Operating mode preselection switched" (see Interface for status information [ 23]) Operating Manual PIT m4SEU | 44 1004648-EN-02...
  • Page 45 MSO1 selected [8h] MSO1 selected [8h] [5h] MSO2 selected [9h] SIo0 ... SIo3 Output MSO1 Fig.: Exiting the operating mode preselection after the pushbutton has been operated, with DIP switch setting [D5] to [D8] Operating Manual PIT m4SEU | 45 1004648-EN-02...
  • Page 46 Preventing the switching of operating mode outputs "1" signal Enabling the switching of operating mode outputs display MSO Display element is lit Output Interface for control information SIo0 ... SIo3 Output MSO Operating mode outputs Operating Manual PIT m4SEU | 46 1004648-EN-02...
  • Page 47: Installation

    Use the notch on the rear of the device to attach it to a mounting rail (35 mm). When installed vertically: Secure the device by using a fixing element (e.g. retaining bracket or end angle). Dimensions in mm Fig.: Front view (installed on top-hat rail) Operating Manual PIT m4SEU | 47 1004648-EN-02...
  • Page 48 Installation 37.2 Fig.: View from below Operating Manual PIT m4SEU | 48 1004648-EN-02...
  • Page 49: Wiring

    IDo0 ... IDo3 Key ID interface: Semiconductor outputs for sending the out- put signals to the controller The function of the terminals depends on the communication mode that has been configured. Operating Manual PIT m4SEU | 49 1004648-EN-02...
  • Page 50: Connecting The Unit

    2. Connect PITreader a Connect the PITreader via the PITreader interface. The PITreader is supplied from the 24V/0V voltage outputs on the PIT m4SEU in order to avoid potential differences. The connections of RxD and TxD on the PIT m4SEU should be crossed. The cable length between the two devices may be max.
  • Page 51: Connection To A Controller

    The cables for the device's supply voltage (A1, A2) contain a 4 A fuse, characteristic B/C. NOTICE After wiring, the PIT m4SEU must be subjected to a full function test in the plant. INFORMATION The inputs on the FS-PLC operating mode evaluation module cannot be configured with test pulse monitoring.
  • Page 52 Wiring Connection for transmitter-controlled communication mode Fig.: Connection for transmitter-controlled communication mode (example) Operating Manual PIT m4SEU | 52 1004648-EN-02...
  • Page 53 Wiring Connection for handshake-controlled communication mode Fig.: Connection for handshake-controlled communication mode (example) Operating Manual PIT m4SEU | 53 1004648-EN-02...
  • Page 54 Wiring Connection for advanced communication mode Fig.: Connection for advanced communication mode (example) Operating Manual PIT m4SEU | 54 1004648-EN-02...
  • Page 55: Operation

    Operation Switch-on behaviour INFORMATION After the PIT m4SEU is switched on (power-on) or after supply voltage is re- turned (reset), operating mode OM1 or the most recently selected operating mode is selected automatically, depending on the device configuration. This also applies if no transponder key is inserted or if a transponder key is de- tected but is invalid.
  • Page 56: Select Operating Modes Om1

    3. Complete operating mode selection a Complete the operating mode selection by removing the transponder key. Once you have removed the transponder key, the PIT m4SEU behaves in accord- ance with the configuration (see Switching behaviour after permission is removed [ 22]).
  • Page 57: Select Special Mode (Service)

    3. Complete operating mode selection a Complete the operating mode selection by removing the transponder key. Once you have removed the transponder key, the PIT m4SEU behaves in accord- ance with the configuration (see Switching behaviour after a transponder key is removed [ 22]).
  • Page 58: Monitoring Of Operating Time

    Two LEDs are available on the top of the device to display the device status. Colour State Meaning Power/Fault Green Voltage supply connected, the device is in a RUN state The device is in a STOP state Access Yellow Valid permission has been transferred from the PITreader Operating Manual PIT m4SEU | 58 1004648-EN-02...
  • Page 59: Troubleshooting

    Operation Troubleshooting If an error occurs on the PIT m4SEU, the last operating mode to be set will be retained. Error Possible cause Remedy Unable to switch the op- Multiple pushbuttons oper- Make sure that only one push- erating mode...
  • Page 60: Status Information About The Signal Outputs O1

    No permission for OM3 or Operating mode lock active No permission for OM4 or Operating mode lock active Only when operating mode is preselected OM2 is preselected, but OM1 is still active MSO1 has a "1" signal Operating Manual PIT m4SEU | 60 1004648-EN-02...
  • Page 61 * OM serves only as an example. One of the operating modes must always light or flash. ** Display element for the newly selected operating mode and all other display elements flash alternately Operating Manual PIT m4SEU | 61 1004648-EN-02...
  • Page 62: Technical Details

    Reaction time change of operating mode depending on the request t2 200 ms Operating time button 1 ... 4 50 ms ... 5 s Operating time, service button 5 s ... 10 s Operating Manual PIT m4SEU | 62 1004648-EN-02...
  • Page 63 Max. cable length 1000 m Material Bottom Front Connection type Spring-loaded terminal, plug-in Mounting type plug-in Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector 0,2 - 2,5 mm², 24 - 12 AWG Operating Manual PIT m4SEU | 63 1004648-EN-02...
  • Page 64: Safety Characteristic Data

    EN 61508-6 and IEC 61511 and as the proof test interval and mission time in accordance with EN 62061. All the units used within a safety function must be considered when calculating the safety characteristic data. Operating Manual PIT m4SEU | 64 1004648-EN-02...
  • Page 65 Measures against CCF (min. score of 65 in accordance with Table F.1 (EN ISO 13849-1) can be considered to have been fulfilled if the user can confirm that the items marked "Customer" have been fulfilled (see table below). Operating Manual PIT m4SEU | 65 1004648-EN-02...
  • Page 66 A safety function's SIL/PL values are not identical to the SIL/PL values of the units that are used and may be different. We recommend that you use the PAScal software tool to calculate the safety function's SIL/PL values. Operating Manual PIT m4SEU | 66 1004648-EN-02...
  • Page 67: Order Reference

    1x PITreader key adapter horizontal + 1x nut for PITreader base 402 308 apter h unit PIT m4SEU terminal 1 set of spring-loaded terminals for PIT m4SEU (1 x 4-pin, 1 x 8-pin 402 306 set spring load and 1 x 12-pin), straight cable outlet Operating Manual PIT m4SEU...
  • Page 68: Ec Declaration Of Conformity

    European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/downloads. Authorised representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ostfildern, Germany Operating Manual PIT m4SEU...