Pilz PSSnet SHL Series Manual

Pilz PSSnet SHL Series Manual

Devices managed ethernet switches

Advertisement

Quick Links

PSSnet SHL Series – Devices
Managed Ethernet Switches
Industrial Ethernet Switches – PSSnet S
Installation – Mat - No. 22750 – EN - 01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSSnet SHL Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pilz PSSnet SHL Series

  • Page 1 PSSnet SHL Series – Devices Managed Ethernet Switches Industrial Ethernet Switches – PSSnet S Installation – Mat - No. 22750 – EN - 01...
  • Page 2 All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received. ® ® ® ® ® ® ® ® ®...
  • Page 3: Table Of Contents

    Content Content Safety instructions ¢ About this manual Device description Description of the device variants 1.1.1 Combination options for PSSnet SHL 1.1.2 Number of ports and media for PSSnet SHL.. Assembly and start-up Installing the device 2.1.1 Unpacking and checking 2.1.2 Installing the SFP modules (optional) 2.1.3 Insert data in label area 2.1.4 Adjust DIP switch settings...
  • Page 4: Safety Instructions

    SELV circuits with the voltage restrictions in accordance with IEC/EN 60950-1. The supply voltage is electrically isolated from the housing. Use only undamaged parts. PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str.2, 73760 Ostfildern, Deutschland...
  • Page 5 Only use connection cables that are permitted for the specified tem- perature range. PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str. 2, 73760 Ostfildern, Deutschland...
  • Page 6 Provisions shall be made to prevent the rated voltage from being ex- ceeded by transient disturbances of more than 40%. EN 60079-0 : 2006 EN 60079-15 : 2005 II 3G Ex nA II T3 ... T4 PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str.2, 73760 Ostfildern, Deutschland...
  • Page 7 PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str. 2, 73760 Ostfildern, Deutschland...
  • Page 8 Make sure that the electrical installation meets local or nationally applicable safety regulations. Note on the CE marking The devices comply with the regulations contained in the following Euro- pean directive(s): PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str.2, 73760 Ostfildern, Deutschland...
  • Page 9 After usage, this product must be disposed of properly as electronic waste in accordance with the current disposal regulations of your county / state / country. PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str. 2, 73760 Ostfildern, Deutschland...
  • Page 10: About This Manual

    Client / Server structure. Browser interface ActiveX control for SCADA integration SNMP/OPC gateway The commendations used in this manual have the following meanings: Listing Work step Subheading PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str.2, 73760 Ostfildern, Deutschland...
  • Page 11: Device Description

    With one additional connection, projection remains simple. Product configuration data can be provided by: diagnosis displays displaying the operating parameters a label area for the IP address PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str. 2, 73760 Ostfildern, Deutschland...
  • Page 12: Description Of The Device Variants

    In the column for the port type, the abbreviations F/O (optical fiber) and TP (twisted pair) indicate the media type, while the abbreviations SC and RJ45 indicate the socket type. PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str.2, 73760 Ostfildern, Deutschland...
  • Page 13: Combination Options For Pssnet Shl

    Multimode FX, 100 Mbit/s Singlemode FX, 100 Mbit/s F/O Ports Socket SC Socket Ring redundancy Media Redundancy Protocol Type Table 1: Combination options of device variants PSSnet SHL PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str. 2, 73760 Ostfildern, Deutschland...
  • Page 14: Number Of Ports And Media For Pssnet Shl

    +24V(P1) 0V 0V +24V(P2) FAULT Stand by Stand by V.24 Figure 2: Device variants with 8 * 10/100 Mbit/s ports 1 to 9 – see fig. 1 PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str.2, 73760 Ostfildern, Deutschland...
  • Page 15: Assembly And Start-Up

    Installing the device 2.1.1 Unpacking and checking Check whether the contents of the package are complete (see “Scope of delivery“. Check the individual parts for transport damage. PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str. 2, 73760 Ostfildern, Deutschland...
  • Page 16: Installing The Sfp Modules (Optional)

    Stand by V.24 Figure 4: Label area for IP address of device 1 – IP address of device (label area) 2 – MAC address of device (label) PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str.2, 73760 Ostfildern, Deutschland...
  • Page 17: Adjust Dip Switch Settings

    You can choose between DC or AC voltage when connecting the supply voltage. You use the +24V and 0V pins to connect the AC voltage (see fig. 16). PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str. 2, 73760 Ostfildern, Deutschland...
  • Page 18 Ring redundancy reserve is available. On delivery, there is no ring re- dundancy monitoring. Pull the terminal block off the device and connect the power supply and signal lines. PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str.2, 73760 Ostfildern, Deutschland...
  • Page 19: Installing The Device On The Din Rail Hub, Grounding

    For the ground conductor, use a cable with a cross section of at least 1.0 mm². 2.1.7 Dimension drawings Dimension drawings for PSSnet SHL PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str. 2, 73760 Ostfildern, Deutschland...
  • Page 20: Installing The Terminal Block, Start-Up Procedure

    100 Mbit/s half-duplex mode, 100 Mbit/s full duplex mode 10 Mbit/s half-duplex mode, 10 Mbit/s full duplex mode State on delivery: autonegotiation activated. The socket housing is electrically connected to the front panel. PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str.2, 73760 Ostfildern, Deutschland...
  • Page 21: Display Elements

    Both supply voltages are on Glowing yellow There is only one supply voltage (P1 or P2) on Not glowing Supply voltages P1 and P2 are too low PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str. 2, 73760 Ostfildern, Deutschland...
  • Page 22 3 – Port status LEDs for DSC, ST, SFP LS - link status (green LED) Not glowing No valid connection. Glowing green Valid connection. PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str.2, 73760 Ostfildern, Deutschland...
  • Page 23: Basic Set-Up

    The USB socket has an interface for the local connection of an AutoCon- figuration Adapter PSSnet SCA. It is used for saving/loading the configu- ration data and diagnostic information, and for loading the software. PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str. 2, 73760 Ostfildern, Deutschland...
  • Page 24 Figure 11: Pin assignment of the V.24 interface and wiring to the DB9 connector You will find a description of the V.24 interface in the “Basic Configuration User Manual” on the CD-ROM. PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str.2, 73760 Ostfildern, Deutschland...
  • Page 25: Disassembly

    To take the device off the DIN rail, insert a screwdriver horizontally un- der the housing into the locking slide, pull it (without tipping the screw- driver) downwards and lift the device upwards. PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str. 2, 73760 Ostfildern, Deutschland...
  • Page 26: Technical Data

    Class 1 according to EN 60825-1 (2001) Protection class IP 20 EMC and immunity EMC interference immunity IEC/EN 61000-4-2 Electrostatic discharge Contact discharge 4 kV Air discharge 8 kV PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str.2, 73760 Ostfildern, Deutschland...
  • Page 27 EN 61850-3 Network range TP port Length of a twisted pair segment max. 100 m / 300 ft Table 4: TP port 10BASE-T / 100BASE-TX PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str. 2, 73760 Ostfildern, Deutschland...
  • Page 28 Installation user manual and CD-ROM Order numbers Name Order number PSSnet SHL 8T MRP 380 601 PSSnet SHL 6T 2FMMSC MRP 380 602 PSSnet SHl 6T 2FMMSC MRP 380 650 PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str.2, 73760 Ostfildern, Deutschland...
  • Page 29 List of norms and standards. Certified devices are marked with a certification indicator. From the imprint on the device label you will see the current certification status of your device. PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str. 2, 73760 Ostfildern, Deutschland...
  • Page 30 Certifications Standard cUL 508 / CSA C22.2 No.142 ISA 12.12.01 / CSA C22.2 No.213 German Lloyd ATEX RL 94/9 EG Table 8: Certifications PSSnet SHL Pilz GmbH & Co. KG, Felix Wankel Str.2, 73760 Ostfildern, Deutschland...
  • Page 31: A Further Support

    Further support Technical questions and training courses In the event of technical queries, please contact your local Pilz distributor or Pilz office. You can find the addresses of our distributors on the Internet: www.pilz.de. Our support line is also at your disposal: Tel.