Battery Care; Activating A Dry-Charged Battery; Electrolyte; Recharging A Battery - Atlas Copco XA186 Dd Instruction Manual

Portable compressor
Hide thumbs Also See for XA186 Dd:
Table of Contents

Advertisement

XAS136/186 Dd
4.7
B
ATTERY CARE
Before handling batteries, read the relevant safety
precautions and act accordingly.
An ASB (Service Bulletin) dealing elaborately with batteries and due
care is available on request.
If the battery is still dry,it must be activated as described in point
4.7.1.
The battery must be in operation within 2 months from being
activated; if not, it needs to be recharged first.
4.7.1 A
CTIVATING A DRY
Ð
Take out the battery.
Ð
Battery and electrolyte must be at equal temperature above 10 ¡C.
Ð
Remove cover and/or plug from each cell.
Ð
Fill each cell with electrolyte until the level reaches 10 to 15 mm
above the plates, or to the level marked on the battery.
Ð
Rock the battery a few times so that possible air bubbles can
escape; wait 10 minutes and check the level in each cell once
more; if required, add electrolyte.
Ð
Refit plugs and/or cover.
Ð
Place the battery in the compressor.
4.7.2 E
LECTROLYTE
Read the safety instructions carefully
Electrolyte in batteries is a sulphuric acid solution in distilled water.
The solution must be made up before being introduced into the
battery.
4.7.3 R
ECHARGING A BATTERY
Before and after charging a battery, always check the electrolyte level
in each cell; if required, top up with distilled water only. When
charging batteries, each cell must be open, i.e. plugs and/or cover
removed.
Use a commercial automatic battery charger according
to its manufacturer's instructions.
Apply with preference the slow charging method and adjust the
charge current according to the following rule of thumb:
battery capacity in Ah divided by 20 gives safe charging current in
Amp.
20
-
CHARGED BATTERY
4.7.4 B
ATTERY MAINTENANCE
Ð
Keep the battery clean and dry
Ð
Keep the electrolyte level at 10 to 15 mm above the plates or at
the indicated level; top up with distilled water only.
Ð
Keep the terminals and clamps tight, clean, and lightely covered
petroleum jelly.
4.8
S
TORAGE
Run the compressor regularly, e.g. twice a week, until warm.
Load and unload the compressor a few times to operate the unloading
and regulating components. Close the air outlet valves after stopping.
If the compressor is going to be stored without running
from time to time, protective measures must be taken as
described in a separate Service Bulletin (ASB), which
may be obtained on request.
4.9
S
ERVICE KITS
A service kit is a collection of parts to fit a specific repair or
rebuilding task.
It guarantees that all necessary parts are replaced at the same time
which improves the uptime of the unit.
The order numbers of the Service Kits are listed in the Atlas Copco
Parts List (ASL).
Contact Atlas Copco.
4.10 C
OMPRESSOR ELEMENT OVERHAUL
When a compressor element is due for overhaul, it is recommended
to have it done by Atlas Copco. This guarantees the use of genuine
parts and correct tools with care and precision.
4.11 L
IABILITY
The manufacturer does not accept any liability for any damage
arising from the use of non-original parts and for modifications,
additions or conversions made without the manufacturerÕs approval
in writing.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xahs146 ddXas186 ddXavs136 ddXats156 dd

Table of Contents