In unusual moisture or material conditions, the machine can plug. When unplugging,
follow this procedure:
1. Place all controls in neutral or off, stop motor, disable and lock out power source
before unplugging.
2. Remove the nut, bolt and sliding clean out
door from the bottom of the inlet tube section
of the conveyor. Remove any built up materi-
al. Reinstall door and hardware.
3. Open the tail cover (below).
4. Remove plugged material.
5. Install and secure conveyor and tail covers.
Remove shipping bolts
after receiving
conveyor
Bottom clean-out cover
USC CONVEYORS
UNPLUGGING
Bottom clean-out cover removed
Sliding Clean
Out Door
Page 67