6.2

Calibration

If the deviation during the calibration check has been too high, you can correct this by performing a zero
point adjustment. Press the left (rolling menu) key on the instrument twice to enter the menu. Navigate to
the submenu "Options", using the arrow keys. Confirm your selection using the power button. Navigate to
the submenu "Calibrate" and confirm again. In order to calibrate the instrument, you first have to unlock
the menu item. This is done by entering the serial number of the instrument. The serial number can be
found in the battery compartment or in the top right corner of the display when you switch on the device.
Press the up button several times until the cursor is on the first digit of the serial number. After a few
seconds, this digit will be taken over by the device as the first digit. The other three digits have to be
entered the same way. When the serial number has been entered like this completely, you can confirm it
using the power button. Now hold the moisture meter in one hand and make sure that there is nothing
around (distance of 200 mm) the steel sensors. Press the power button and the calibration will be made
and completed after several seconds. During the calibration, hold the device in your hand freely. The
device is ready to use when the display indication changes.
7

Maintenance

7.1

Storage

Always make sure that the device is never influenced by extreme (environmental) conditions. Protect it
from shocks and temperatures that are too high. Keep in mind that this instrument is not waterproof.
7.2

Troubleshooting

There are certain difficulties that may occur when using this paper moisture meter. The most common
ones are shown here.
7.2.1

Wrong characteristic curve

Make sure that the correct characteristic curve is chosen. The characteristic curve "Reference" cannot be
taken.
7.2.2

Product stack too thin

Single paper sheets cannot be measured. The product stack needs to be at least 100 mm thick.
7.2.3

Electroconductive materials

Electroconductive and other metallic materials can negatively influence your measurements. None of
those are allowed in the distance of 20 cm underneath the test surface.
7.2.4

Product temperature out of the operating conditions

Always pay attention to the operating conditions prescribed within this user manual.
7.2.5

Temperature difference between the meter and the product

The sample and the measurement instrument should be stored in areas with similar environmental
conditions. If the temperature difference is too big, this may affect the accuracy of the instrument.
7.2.6

Measurement at the front side

Measurements cannot be performed at front sides.
7.2.7

Bent steel sensors

If the steel sensors are heavily bent, this may have a negative effect on your measurements.