BLAUBERG Ventilatoren Axis-Q Series User Manual

BLAUBERG Ventilatoren Axis-Q Series User Manual

Industrial electric axial fans

Advertisement

IndustrIal electrIc axIal fans
Axis-Q
Axis-QR
Axis-F
Axis-QA
EN
USER'S MANUAL
Axis-QRA
Tubo-F
Tubo-M(Z)
Tubo-MA(Z)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Axis-Q Series and is the answer not in the manual?

Questions and answers

Summary of Contents for BLAUBERG Ventilatoren Axis-Q Series

  • Page 1 IndustrIal electrIc axIal fans Axis-Q Axis-QRA Axis-QR Tubo-F Axis-F Tubo-M(Z) Axis-QA Tubo-MA(Z) USER’S MANUAL...
  • Page 2: Table Of Contents

    axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de CONTENTS Safety requirements ..................................2 Purpose ........................................ 4 Delivery set ......................................4 Designation key ....................................4 Technical data ....................................5 Unit design and operating principle ..........................10 Mounting and set-up ..................................
  • Page 3 axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de • Do not change the power cable length at your own discretion. • Do not bend the power cable. • Do not lay the power cable of the unit in •...
  • Page 4: Purpose

    axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de PURPOSE THE UNIT SHOULD NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED PHYSICAL, MENTAL, OR SENSORY CAPACITIES, OR THOSE WITHOUT THE APPROPRIATE TRAINING. THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY QUALIFIED PERSONNEL AFTER THE APPROPRIATE BRIEFING.
  • Page 5: Technical Data

    axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de TECHNICAL DATA The corrosive aggressiveness of the handled medium to carbon steels of ordinary quality must be equal to that of air at temperatures ranging from -25 °C to +40/60 °C.
  • Page 6 axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de Axis-Q / Axis-Q / Axis-Q / Axis-Q / Axis-Q / Axis-Q / Axis-Q / Axis-Q / Axis-Q / Axis-Q / Axis-QR / Axis-QR / Axis-QR / Axis-QR / Axis-QR /...
  • Page 7 axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de Dimensions [mm] Weight Model [kg] Ø D Ø d Axis-Q 200 2E Axis-Q Axis-Q 250 2E / Axis-Q 250 2D Axis-Q 250 4E / Axis-Q 250 4D Axis-Q 300 4E / Axis-Q 300 4D 6.1 / 5.4 Axis-Q 300 4E / Axis-Q 300 4D...
  • Page 8 axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de Axis-QA Dimensions [mm] Model Weight [kg] Ø D Ø d Axis-QA 150 Axis-QA 200 Axis-QA 250 Axis-QA 315 Axis-QRA Dimensions [mm] Model Weight [kg] Ø...
  • Page 9 axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de Tubo-M(Z) Dimensions [mm] Model Weight [kg] Ø D Tubo-M(Z) 150 Tubo-M(Z) 200 Tubo-M(Z) 250 Tubo-M(Z) 315 RSM(Z) Tubo-M(Z) RSM(Z) fans are equipped with (polymer-coated steel, galvanized steel) reducers for connection to 150 mm, 200 mm and 250 mm air ducts.
  • Page 10: Unit Design And Operating Principle

    axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de UNIT DESIGN AND OPERATING PRINCIPLE Axis-Q Axis-QR fans consist of a casing 1 with a square or a round flange with a grille fixed with bolts 4 and complete with an electric motor and impeller 5.
  • Page 11: Mounting And Set-Up

    axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de Tubo-F, Tubo-M(Z), Tubo-MA(Z) fans The brackets 2 are attached to the casing with bolts 1. The electric motor with the impeller 4 is mounted on the bracket 3 inside the Tubo-F casing.
  • Page 12 axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de Axis-Q fan installation Axis-QR fan installation...
  • Page 13 axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de Axis-QA and Axis-QRA fan installation...
  • Page 14 axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de Axis-F fan installation The fans are installed into air ducts by means of connection flanges. The fan must be installed in such a way so that the direction of the arrow shown on the casing matches the direction of air flow in the system.
  • Page 15 axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de Tubo-M(Z) fan installation RSM(Z) The fans are installed into air duct by means of an reducer which enables joining different diameter ducts. Once done, the Tubo-M(Z) assembly is secured with clamps.
  • Page 16: Connection To Power Mains

    axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de CONNECTION TO POWER MAINS DISCONNECT THE POWER SUPPLY PRIOR TO ANY OPERATIONS WITH THE UNIT. CONNECTION OF THE UNIT TO POWER MAINS IS ALLOWED BY A QUALIFIED ELECTRICIAN WITH A WORK PERMIT FOR THE ELECTRIC UNITS UP TO 1000 V AFTER CAREFUL READING OF THE PRESENT USER’S MANUAL.
  • Page 17 axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de Axis-Q and Axis-QR fan connection Axis-QA fan connection...
  • Page 18 axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de Axis-F, Tubo-M(Z), Tubo-MA(Z) fan connection Tubo-F fan connection...
  • Page 19: Technical Maintenance

    axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de TECHNICAL MAINTENANCE DISCONNECT THE UNIT FROM POWER SUPPLY BEFORE ANY MAINTENANCE OPERATIONS! All the operations specific to the technical maintenance must be performed upon disconnecting the fan from power mains. The technical maintenance includes periodic cleaning of the fan surfaces from dust and dirt.
  • Page 20 axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de Axis-QA and Axis-QRA technical maintenance Tubo-F, Tubo-M(Z), Tubo-MA(Z) technical maintenance...
  • Page 21: Troubleshooting

    axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de TROUBLESHOOTING PROBLEM POSSIBLE REASONS TROUBLESHOOTING Check the electrical connections and the power No electric power. switch status. The fan will not start on power-up. Switch off the fan.
  • Page 22: Manufacturer's Warranty

    axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de MANUFACTURER’S WARRANTY The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby declare that the product complies with the provisions of Electromagnetic Compatibility (EMC) Directive 2014/30/EU of the European Parliament and of the Council, Low Voltage Directive (LVD) 2014/35/EU of the European Parliament and of the Council and CE-marking Council Directive 93/68/EEC.
  • Page 23: Certificate Of Acceptance

    axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z) www.blaubergventilatoren.de CERTIFICATE OF ACCEPTANCE Unit Type Industrial electric axial fans Model Axis-Q / Axis-QR / Axis-F / Axis-QA / Axis-QRA / Tubo-F / Tubo-M / Tubo-MA _____ Serial Number Manufacture Date Quality Inspector’s...
  • Page 24 www.blaubergventilatoren.de B03EN-11...

This manual is also suitable for:

Axis-qr seriesAxis-f seriesAxis-qa seriesAxis-qra seriesTubo-f seriesTubo-m series ... Show all

Table of Contents