Progres AgroBee-L Manual page 3

Hide thumbs Also See for AgroBee-L:
Table of Contents

Advertisement

Outputs
Number
2
5 Vdc or 12 Vdc (Analog
Type
sensor power supply)
Maximum current: 50 mA
Number
2
6 Vdc, 9 Vdc, 12 Vdc, 19
Type
Vdc Trigger time: 80 ms
Capacitor charge: 4700 µF
Environment
Temperature -10 °C a +60 °C
Moisture
< 95 %
Altitude
2000 m
Pollution
Grade II
Declaration of conformity
This system conforms with the regulations and other
regulatory documents in the following list:
UNE EN 60950-1:2007+ CORR:2007
Electrical
safety
UNE EN 60215:1995 + A2:1995
ETSI EN 301 489-17 v1.3.2 based on ETSI EN 301 489-1 v.1.7.1:
UNE-EN 55016-2-3:2007
UNE-EN 61000-4-2:1997
EMC
+ A1:1999 + A2:2001
UNE-EN 61000-4-3:2007 + A1:2008
UNE-EN 61000-4-4:2005
UNE-EN 61000-4-6:2008
ETSI EN 300 328 v1.7.1
Radio
(Decision ERC/DEC/(01)07
spectrum
and Recommendation
protection
CEPT ERC/REC 70-03)
This symbol indicates that electrical and electronic controller must not be disposed of along
with household waste at the end of its useful life. The product must be taken to the correspon-
ding collection point for the recycling and proper treatment of electrical and electronic contro-
ller in accordance with national legislation.
Inputs
Maximum distance betweeen sensor and
AgroBee-L: 50m
Number
1
Type
For potential-free contacts
Number
2
Type
Analog (12 bits)
Box dimensions GNSS
Height
Width
Depth
Weight (approx.)
Information technology controller.
Safety. Part I: General requirements
Safety requirements for
radiotransmission controller
Radiated radio frequency
emissions (30-1000MHz). Class B
Electrostatic discharge
Electromagnetic field immunity
Transient/burst immunity
Current injection: 150KHz-80MHz
Spurious issuer emissions Coordinator
and Module GNSS. Effective
radiated power Coordinator and
Module GNSS. Frequency drift
Coordinator and Module GNSS.
460 mm
295 mm
590 mm
3,35 Kg
User's manual | AgroBee-L ·