Progres AgroBee-L Manual page 13

Hide thumbs Also See for AgroBee-L:
Table of Contents

Advertisement

CONSULT THE AGROBEE-L MODULE DIGITAL AND ANALOG INPUTS
Menu to check the status of digital inputs, counters, and GNSS inputs.
The information shown on the different screens is as follows:
• Consult the geographic coordinates of the GNSS module position:
‒ Latitude (In xxº yy' zz.zz" N/S format) of the current position
‒ Longitude (In xxº yy' zz.zz" E/W format) of the current position
‒ Angle ("ANG. H") of the current position with respect to the initial (0º) and central
position defined in the parameters: clockwise angle
‒ Angle ("ANG-Z-N") of the initial position defined in parameters relative to geographic
North
‒ Distance from the current point to the point defined as the centre
‒ Number of satellites currently being viewed by the GNSS receiver incorporated into the
module.
‒ State the measured position. If F is 'YES', the GNSS receiver is fixed and the measurement
of the position is correctly displayed. If F is 'NO', it indicates that the GNSS receiver
cannot determine the position.
• Consult digital inputs: For each of the digital inputs available to the module in question, its
status is shown either as '0' (open contact) or '1' (closed contact)
• See accumulated counter sensors: The total number of pulses detected will be displayed for
each digital input configured as a counter sensor. If this entry is not configured as a counter,
the text 'N-A' (Not-Activated) will appear.
• See instant flow rate (time between pulses): The time in [ms] between the last 2 pulses
detected will be displayed for each digital input that is configured as a counter sensor. If this
entry is not configured as a counter, the text 'N-A' (Not-Activated) will appear.
• Consult analog inputs: For each of the available analog inputs, the value read is displayed
and expressed in [mA] or [V] according to the type of input in question. Likewise, the value
in the format in which the Agrónic receives it (800-4000mV) is shown in parentheses. If the
analog input in question is not configured, the text 'N-A' (Not-Activated) will appear.
• Check the supply voltage of the analog sensors: The value of the supply voltage sent to the
active analog sensors is displayed in [mV].
From the Agrónic, press the '1' key in the module's consultation screen on the Agrónic to view
the analog/digital values of the GNSS inputs.
Nomenclature used in these consultations: