Progres AgroBee-L Manual page 12

Hide thumbs Also See for AgroBee-L:
Table of Contents

Advertisement

- Communication error
- Model error
- Does not communicate
∙ Signal-Noise ratio of the last received message: Reliable communication if >40%.
‒ Time until next radio emission: time in [s]
‒ Status of the last 16 communications (the previous communications appear on the right
side of the screen):
∙ 1: It indicates that the emission has been made and the correct information received in
the last communication
∙ 0: Indicates that the radio emission has been made, but the correct data has not been
received or no data has been received
Part of this information is available through the Agrónic by accessing "Consultation | Commu-
nications | AgroBee", where you can also see the query regarding the controller and the parame-
ters of the communication.
CONSULT COMMUNICATIONS
AgroBee-L 868
Status: Correct
Timing: 60"
Channel: 01
TX Mode: 05
Network code: 00001
CONSULT THE AGROBEE-L MODULE DIGITAL OUTPUTS
Menu that shows the status of each of the outputs, one by one.
The states that can be shown for each digital latch output are the following:
• Activated
• Stopped
• Latch tension load (running)
• Latch tension load (stopped)
• Running time
• Stopped time
The status of the digital outputs (latch) can also be displayed through the Agrónic: see the next
section.
12
· User's manual | AgroBee-L
CONSULT COMMUNICATIONS
M01 (ns. 236) V1.00
Status: Correct (40")
Level: 80% / 82%
Vbat: 04.0 V
Vsol: 05.8 V
1111111111111111