Operation - Field Controls Healthy Home System Trio-16 Manual

Whole house air purification system
Table of Contents

Advertisement

OPERATION

The Trio Air Purifi cation System installs in the air-inlet side of any heating and airconditioning system up to fi ve tons
in size. Only operation of the air-handler fan unit is required for air purifi cation and sterilization to take place.
NOTE: The UVC germicidal lamps are wired to operate continuously. This feature allows the catalyst to burn off
NOTE:
surface impurities, cleaning and reactivating itself during periods of non-use or no airfl ow. The cost of operation is
less than .07 cents per day. See operating cost section.
The Trio Air Purifi cation System combines three unique technologies to protect people against indoor air pollutants.
Photo catalytic technology (PCO) combined with high effi ciency electro-statically super charged MERV13 particu-
late fi lter and UVC germicidal light quickly reduces and eliminated toxic gas-phase chemicals, lung damaging dust
and airborne germs from the living environment.
Many new homes have smart programmable thermostats that allow for automatic operation of the air-handler fan
unit when there is no demand for heating or air conditioning. It is important that the TRIO Air Purifi cation System is
operating at least 20-30 minutes per hour (24) hours per day to remove airborne contaminants from the indoor
environment.
Individuals that are sensitive to mold spores, dust mites, chemicals or have respiratory problems such as asthma,
emphysema, and chronic allergies should extend the run time to (40) minutes or more per hour.
Fan unit on for 10 minutes per hour
Fan unit on for 15 minutes per hour
Fan unit on for 20 minutes per hour
Fan unit on for 30 minutes per hour
NOTE: In the event, the existing thermostat does not have the capability to operate the air-handler fan unit
NOTE:
independently of a demand for heating or air-conditioning, it is highly recommended to install the Field Controls
Healthy Home System Control Plus (HHSC+) programmable ventilation system (included with -HHS models).
This device is simply wired in parallel with the existing thermostat and can be programmed to turn on the air
handler fan unit for any desired interval. A memory tracks the time the fan unit operates every hour and only
cycles the fan unit that hour if normal requirements for heating and air conditioning have not cycled the fan unit
long enough to meet air purifi cation requirements.
COST OF CONTINUOUS (24) HR PER DAY OPERATION PER MONTH
Electricity cost
per kilowatt hour
TRIO (32.25 kw hours)
cost per month
During periods where the fan unit is being operated for the sole purpose of air purifi cation, usually during
the spring and fall season when there is no requirement for heating or cooling, the cost of running a 1/2
horsepower fan unit will add approximately $5.36 per month to the normal operating cost. However, this cost is
easily off set in savings on medication, doctors offi ce visits, mechanical maintenance and cleaning of fan units,
refrigeration coils, dirty air ducts and last but not least, less house cleaning.
WARNING:
Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage
or blindness.Never operate the Trio Air Purifying System out of the ductwork. Avoid touching the glass portion of the lamp with your hands.
P/N 780105101 11/20 Rev B
AIR CYCLES PER HOUR
Fan unit on for 10 minutes per hour Air cycled(1) ------- times per hour
Fan unit on for 15 minutes per hour Air cycled(1.3) ----- times per hour
Fan unit on for 20 minutes per hour Air cycled(1.75) ---- times per hour
Fan unit on for 30 minutes per hour Air cycled(2.62) ---- times per hour
AIR CYCLES PER DAY
(Based on 3000 sq. ft.)
Air cycled(24) ------ times per day
Air cycled(31) ------ times per day
Air cycled(42) ------ times per day
Air cycled(63) ------ times per day
.06 kw hr.
.08 kw hr.
$1.93
$2.58
Page 4 of 12
.10 kw hr.
$3.22

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Healthy Home System Trio-16 and is the answer not in the manual?

Questions and answers

Table of Contents