CHANGING THE PARTICULATE REMOVAL CARTRIDGE (FILTER)
1.
Unplug the power cord from the Trio.
2.
Remove the door to the unit per the steps listed previously.
3.
Remove old fi lter cartidge and replace with new fi lter. Make sure airfl ow arrow on fi lter is pointing to the
inside of module. (See Figure 13)
4.
Replace the door on the unit per the steps listed previously. Return power to unit.
TROUBLESHOOTING GUIDE
1.
Check to be sure there is correct voltage to the unit and the ballast is set for the correct voltage.
2.
Be sure the lamp connector is fastened securely.
3.
Check for loose electrical connections.
4.
Test with new lamp and if lamp still does not light, replace ballast.
REPLACEMENT PARTS LIST
WARNING:
Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage
or blindness.Never operate the Trio Air Purifying System out of the ductwork. Avoid touching the glass portion of the lamp with your hands.
P/N 780105101 11/20 Rev B
FIGURE 12
Replacement Part Number
46636400
46683600
BTO-12/20 Replacement Ballast Assembly
731011325
TRIO1625rm13C Merv 13 Filter w/ Carbon
731012025
TRIO2025rm13C Merv 13 Filter w/ Carbon
808021200
Catalytic Aluminum Substrate (Trio-16 & Trio-16-HHS)
808022000
Catalytic Aluminum Substrate (Trio-20 & Trio-20-HHS)
For replacement parts, contact Field Controls at:
Phone: 252-522-3031 • Fax: 252-522-0214
Email: sales@fi eldcontrols.com
Page 10 of 12
Replacement UVC Lamps (Set of 2)
FIGURE 13
Need help?
Do you have a question about the Healthy Home System Trio-16 and is the answer not in the manual?
Questions and answers