The Duo-2000 produces germicidal UVC Band light rays, which sterilize and reduce airborne microorganisms and
reduce Volatile Organic Compounds (VOC's) by a combination of photocatalytic chemical reaction and carbon
absorption as air passes through a heating or air conditioning system. They are installed in the main supply or
return duct and operate continuously to automatically purify the air in the home 24 hours a day.
This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition,
nor for use in the mitigation, treatment, or prevention of any disease or condition.
WARNING:
WARNING: Do not
Do not exceed voltage rating. Severe damage to device and or fi re could result. Verify
proper voltage.
proper voltage.
This device MUST be installed by a qualifi ed agency in accordance with the manufacturer's installation instructions. The defi nition of
a qualifi ed agency is: any individual, fi rm, corporation or company which either in person or through a representative is engaged
in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the
precautions required, and has complied with all the requirements of the authority having jurisdiction.
Installed By:
Models: Duo-2000
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY
BEFORE PROCEEDING WITH THE INSTALLATION.
BEFORE PROCEEDING WITH THE INSTALLATION.
exceed voltage rating. Severe damage to device and or fi re could result. Verify
Please retain these instructions after installation.
Phone:
www.fi eldcontrols.com
ITEMS INCLUDED:
1 - Duo-2000 Air Purifi er
1 - 120V Quick Connect Power Cord
1 - UVC Germicidal Lamp
4 - #8 Sheet Metal Mounting Screws
1 - Instruction Sheet
1 - Duct Board Mounting Plate
Installation Date:
P/N 46638600 09/18 Rev E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Healthy Home System Duo-2000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Field Controls Healthy Home System Duo-2000

  • Page 1 PHOTO-CATALYTIC AIR PURIFIER Models: Duo-2000 *includes carbon fi lter ITEMS INCLUDED: 1 - Duo-2000 Air Purifi er 1 - 120V Quick Connect Power Cord 1 - UVC Germicidal Lamp 4 - #8 Sheet Metal Mounting Screws 1 - Instruction Sheet 1 - Duct Board Mounting Plate The Duo-2000 produces germicidal UVC Band light rays, which sterilize and reduce airborne microorganisms and reduce Volatile Organic Compounds (VOC’s) by a combination of photocatalytic chemical reaction and carbon...
  • Page 2 (THIS PAGE LEFT INTENTIONALLY BLANK) WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.Never operate the Duo-2000 Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. Page 2 of 12 P/N 46638600 09/18 Rev E...
  • Page 3: Safety Considerations

    SAFETY CONSIDERATIONS WARNING: Never expose eyes or skin to UVC light from any source. WARNING: Never expose eyes or skin to UVC light from any source. • Looking directly at the UVC light may cause permanent eye damage or blindness. •...
  • Page 4 HVAC system. For best results, the HVAC air fi lter should be upgraded to a Field Controls High Effi ciency FC8 or FC11 pleated media air cleaner. Do not locate the Duo-2000 Field Controls High Effi ciency FC8 or FC11 pleated media air cleaner. Do not locate the Duo-2000 within 24 inches (direct exposure) of plastic materials or air fi...
  • Page 5 DUO MODEL INSTALLATION INSTRUCTIONS Choose a location for the Duo unit, with the following considerations: a. The Duo unit will reduce organic buildup on an HVAC cooling/heating coil by illumination with UVC germicidal rays. Locate the Duo such that the maximum surface area of the coil is illuminated, while installing as close to the coil as possible without damage to the coil.
  • Page 6: Maintenance

    FIGURE 5 FIGURE 6 MAINTENANCE WARNING: Disconnect power to the transformer before commencing WARNING: Disconnect power to the transformer before commencing inspection inspection and cleaning. and cleaning. NOTE: Wear disposable, non-absorbent protective gloves prior to inspection procedure in case of accidental breakage of glass.
  • Page 7: Replacing The Lamp

    REPLACING THE LAMP Recommended every (24) months of continuous service. Recommended every (24) months of continuous service. Replace only with a Part # 46636300 17.5 LAMP UVC germicidal replacement lamp. This is a custom Replace only with a Part # 46636300 17.5 LAMP UVC germicidal replacement lamp. This is a custom manufacture lamp designed only for high output thermal compensating electronic ballast.
  • Page 8 HONEYCOMB AND CARBON REPLACEMENT If there is a need to replace the Pro-Cell honeycomb or carbon media, the subsequent procedure should be followed. WARNING: WARNING: Make sure power is disconnected from the unit before removing the unit. Make sure power is disconnected from the unit before removing the unit. NOTE: Wear disposable non-absorbent protective gloves prior to replacement procedure in case of accidental breakage of glass.
  • Page 9: Troubleshooting Guide

    TROUBLESHOOTING GUIDE 1. Check to be sure there is correct voltage to the unit and the ballast is set for the correct voltage. 2. Be sure the lamp connector is fastened securely. 3. Check for loose electrical connections. 4. Test with new lamp and if lamp still does not light, replace ballast. SPECIFICATIONS Duo-2000 UVC Photo-Catalytic Air Purifi...
  • Page 10: Replacement Parts List

    120/240V Rep Ballast Assy 730118175 Carbon, Duo-2000 80213041175 Pro-Cell Honeycomb 4.125 x 17.625 For replacement parts, contact Field Controls at: Phone: 252-522-3031 • Fax: 252-522-0214 Email: sales@fi eldcontrols.com CLEAN-UP OF BROKEN LAMPS (see warnings on page 3 of this manual) UV lamps contain a small amount of mercury, like a typical fl...
  • Page 11 (THIS PAGE LEFT INTENTIONALLY BLANK) WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.Never operate the Duo-2000 Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. Page 11 of 12 P/N 46638600 09/18 Rev E...
  • Page 12 This manual may be downloaded and printed from the Field Controls website (www.fi eldcontrols.com) This manual may be downloaded and printed from the Field Controls website (www.fi eldcontrols.com) WARRANTY WARRANTY For warranty information about this or any Field Controls product, visit: For warranty information about this or any Field Controls product, visit: www.fi...