TRIO WHOLE HOUSE AIR PURIFICATION SYSTEM
TRIO Air Purifi cation System installs into the return sided of ducted HVAC appliances. Most electronic and media air
cleaners only capture particles. The TRIO electronic air purifi er not only removes particles, but also attacks viruses,
germs, and toxic gases.
This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition, nor
for use in the mitigation, treatment, or prevention of any disease or condition.
WARNING: Do not
WARNING:
Do not exceed voltage rating. Severe damage to device and or fi re could result. Verify
proper voltage.
proper voltage.
This device MUST be installed by a qualifi ed agency in accordance with the manufacturer's installation instructions. The defi nition of
a qualifi ed agency is: any individual, fi rm, corporation or company which either in person or through a representative is engaged
in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the
precautions required, and has complied with all the requirements of the authority having jurisdiction.
Installed By:
Models: Trio-16, Trio-20, Trio-16-HHS, Trio-20-HHS
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY
BEFORE PROCEEDING WITH THE INSTALLATION.
BEFORE PROCEEDING WITH THE INSTALLATION.
exceed voltage rating. Severe damage to device and or fi re could result. Verify
Please retain these instructions after installation.
Phone:
www.fi eldcontrols.com
ITEMS INCLUDED:
1 - Trio-16 or Trio-20 Air Purifi cation System
1 - 120V Quick Connect Power Cord
2 - UVC Germicidal Lamp
1 - Instruction Sheet
1 - Lens Label
1 - HHSC Control (only with HHS models)
Installation Date:
P/N 780105101 11/20 Rev B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Healthy Home System Trio-16 and is the answer not in the manual?

Questions and answers

Summary of Contents for Field Controls Healthy Home System Trio-16

  • Page 1 TRIO WHOLE HOUSE AIR PURIFICATION SYSTEM Models: Trio-16, Trio-20, Trio-16-HHS, Trio-20-HHS ITEMS INCLUDED: 1 - Trio-16 or Trio-20 Air Purifi cation System 1 - 120V Quick Connect Power Cord 2 - UVC Germicidal Lamp 1 - Instruction Sheet 1 - Lens Label 1 - HHSC Control (only with HHS models) TRIO Air Purifi cation System installs into the return sided of ducted HVAC appliances.
  • Page 2: Safety Considerations

    SAFETY CONSIDERATIONS WARNING: Never expose eyes or skin to UVC light from any source. WARNING: Never expose eyes or skin to UVC light from any source. • Looking directly at the UVC light may cause permanent eye damage or blindness. •...
  • Page 3: Specifications

    SPECIFICATIONS Model Trio 20: Model Trio 16: (Capacity 1.5 to 4.0 tons) (Capacity 1.5 to 3.0 tons) Model: Trio 20/Trio-20-HHS Model: Trio 16/Trio-16-HHS Power: 120V/60 Hz .6 Amps 49.2 Watts Power: 120V/60 Hz .6 Amps 49.2 Watts Fuse: Replace only with AGC-2 fuse Fuse: Replace only with AGC-2 fuse Application: 1.5 to 4.0 Ton Drive Air Handler/Furnace Application: 1.5 to 3 Ton Drive Air Handler/Furnace...
  • Page 4: Operation

    NOTE: In the event, the existing thermostat does not have the capability to operate the air-handler fan unit independently of a demand for heating or air-conditioning, it is highly recommended to install the Field Controls Healthy Home System Control Plus (HHSC+) programmable ventilation system (included with -HHS models).
  • Page 5 REMOVING & REPLACING THE DOOR To remove the door to the Trio system follow these steps: Twist the two locking knobs such that they are vertical to the short edge of the unit. (See Figure 1) Remove the door at an angle, from the knob side fi rst. (See Figure 2) FIGURE 1 FIGURE 2 To replace the door to the Trio system follow these steps:...
  • Page 6: Installation

    WARNING: Make sure unit is unplugged before installing the lamp. WARNING: Make sure unit is unplugged before installing the lamp. INSTALLATION Make sure to install the Trio Healthy Home Purifi cation System so that the inlet or return air enters the side containing the MERV13 particulate reduction cartridge fi rst.
  • Page 7 FIGURE 7 FIGURE 8 Seal all seams with an approved air duct sealant between the air handler and the outlet side of the Trio so that there can be no air bypassing the system. Attach the air handler to the outlet side of the Trio and fasten with #10 x 3/8 self-drilling sheet metal screws.
  • Page 8: Maintenance

    The sticker is designed to handle two Filter replacements to every one UV Lamp replacement. The replacement dates must be manual written on the sticker by the homeowner or HVAC contractor. The fi lter/lamp replacement sticker can be purchased from Field Controls as a separate item. WARNING: Never expose eyes or skin to UVC light from any source.
  • Page 9: Replacing The Lamp

    CLEANING THE LAMP WARNING: WARNING: Disconnect power to the transfomer Disconnect power to the transfomer or unplug or unplug the the120V power 120V power cord before starting cord before starting replacement procedure replacement procedure. NOTE: Wear disposable, non-absorbent protective gloves prior to replacement procedure in case of accidental breakage of glass.
  • Page 10: Troubleshooting Guide

    808021200 Catalytic Aluminum Substrate (Trio-16 & Trio-16-HHS) 808022000 Catalytic Aluminum Substrate (Trio-20 & Trio-20-HHS) For replacement parts, contact Field Controls at: Phone: 252-522-3031 • Fax: 252-522-0214 Email: sales@fi eldcontrols.com WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.Never operate the Trio Air Purifying System out of the ductwork.
  • Page 11: Wiring Diagram

    CLEAN-UP OF BROKEN LAMPS UV lamps contain a small amount of mercury, like a typical fl uorescent lamp. DO NOT touch any of the mercury with your bare hands. While wearing disposable, non-absorbent protective gloves, carefully pick up the large pieces of glass with your hands.
  • Page 12 This manual may be downloaded and printed from the Field Controls website (www.fi eldcontrols.com) This manual may be downloaded and printed from the Field Controls website (www.fi eldcontrols.com) WARRANTY WARRANTY For warranty information about this or any Field Controls product, visit: For warranty information about this or any Field Controls product, visit: www.fi eldcontrols.com...

Table of Contents