Field Controls UV-AIRE UV-12 Owner's Manual

Field Controls UV-AIRE UV-12 Owner's Manual

Field controls air purifying system owner's manual
Hide thumbs Also See for UV-AIRE UV-12:

Advertisement

UV-AIRE
UV-C light inhibits the growth and reproduction of germs and bacteria that circulate through a home's
heating and air conditioning system. The treatment is a safe, silent, and proven way to make your home a
healthier place to live.
SAFETY CONSIDERATIONS
WARNING: Never expose eyes or skin to UV-C light from any source.
Looking directly at the UV-C light may cause permanent eye damage or blindness.
Never operate the UV-Aire Air Purifying System out of the plenum.
Designed for a closed duct system. Do not mount near a return air opening
All duct openings in direct line of site of the UV light must be sealed with duct tape or equivalent
sealing methods.
WARNING: UV light will break down plastic materials not rated for UV exposure:
(Examples: wire insulation, flex duct, drain pans and humidifiers)
The unit must be mounted at least 30" from the above stated type of materials.
If it is necessary to mount the unit in direct line of sight of these types of materials, they must be
shielded with aluminum foil, aluminum foil tape, or sheet metal.
WARNING: DO NOT mount this unit outdoors.
This product is designed for indoor installation only (i.e. attics, crawl spaces, basements, etc.).
AFTER OPENING THE CARTON, UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE.
DO NOT INSTALL THIS UNIT IF ANY DAMAGE IS NOTICEABLE.
This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for
use in the mitigation, treatment, or prevention of any disease or condition.
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.
This device MUST be installed by a qualified agency in accordance with the manufacturer's installation instructions. The definition of
a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged
in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the
precautions required, and has complied with all the requirements of the authority having jurisdiction.
Installed By:
AIR PURIFYING SYSTEM
®
MODEL: UV-12, UV-18
Please retain these instructions after installation.
Phone:
www.fieldcontrols.com
ITEMS INCLUDED IN KIT:
1- UV-Aire power unit
4- Sheet metal mounting screws
1- Angled mounting bracket
1- Flat mounting bracket
1- Duct board mounting bracket
1- Ultraviolet lamp
1- Instruction Sheet
1- Wing nut
Caution Labels
Gasket
Installation Date:

Advertisement

Table of Contents
loading

Summary of Contents for Field Controls UV-AIRE UV-12

  • Page 1 HVAC appliances, who is experienced in such work, familiar with all the precautions required, and has complied with all the requirements of the authority having jurisdiction. Installed By: AIR PURIFYING SYSTEM MODEL: UV-12, UV-18 ITEMS INCLUDED IN KIT: 1- UV-Aire power unit 4- Sheet metal mounting screws...
  • Page 2: Indication For Use

    Minimum Model Volts Duct Width UV-12 UV-18 WARNING: Before installing or servicing a humidifier, air filter, heat system, or this unit, etc., always turn all power OFF and have units unplugged. Electrical shock can cause personal injury or death. Never expose eyes or skin to direct UV-C light from any source.
  • Page 3 IF YOU HAVE FLEX DUCT: For installations on duct systems with a metallic main duct and flex duct branches, follow the instructions in figure 2A below. IF YOU HAVE METAL DUCT: Apply supplied wet and stick mounting template to air duct in either a vertical or horizontal position as shown in Figure 2B.
  • Page 4 IF YOU HAVE DUCT BOARD: Mount the supplied metal mounting plate onto the duct with duct tape in either a vertical or horizontal position as shown in Figures 2B and 3. Bend tabs outward as shown in Figure 4. Using a knife or blade, cut out a rectangle opening in the duct using the mounting plate as a template. (See Figure 5) Remove the cut piece of duct.
  • Page 5 Determine whether to use flat or angled bracket. (Refer to UV-Aire “Bulb Mounting Bracket Selection” for aid in this decision) a. Flat Bracket Installation i. Remove the two hex nuts and flat bracket from included bagged hardware. ii. Install the flat bracket and secure to the unit base with the hex nuts provided.
  • Page 6 Replace cover on unit. Tighten side screws. (See Figures 19 & 20) Plug the power cord into a standard electrical outlet. NOTE: Seal the joints and seams of the plenum near the mounting location to reduce any direct viewing of light. (See Figure 1) Flip switch on box to the ON position.
  • Page 7: Maintenance

    ANGLED LAMP MOUNTING BRACKET SPECIFICATIONS Use the specifications below to determine allowable clearances for proper mounting of the UV-Aire unit on the duct. Unit UV-12 UV-18 MAINTENANCE Inspect and clean lamp at least every 6 months. Replace your UV-Aire Air Purifying System lamp once a year to maintain the lamp’s maximum output intensity.
  • Page 8: Replacement Parts List

    Field Controls Direct Vent Systems (FDVS), Field Oil Vent Kits (FOVP), and ComboVents (CV). Field Controls warrants that the products listed below shall be free from defects in material and workmanship under normal use for the limited period indicated, from the date of purchase by the consumer, subject to the provisions 1-8 below.

This manual is also suitable for:

Uv-aire uv-18

Table of Contents