HEALTHY HOME AIR PURIFICATION SYSTEM
MODELS:
TRIO 1200 & TRIO 2000
INSTALLATION AND OPERATION
Field Controls, 2630 Airport Road, Kinston, NC 28504
*(252)522-3031*
www.fi eldcontrols.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the Healthy Home System and is the answer not in the manual?

Questions and answers

Summary of Contents for Field Controls Healthy Home System

  • Page 1 HEALTHY HOME AIR PURIFICATION SYSTEM MODELS: TRIO 1200 & TRIO 2000 INSTALLATION AND OPERATION Field Controls, 2630 Airport Road, Kinston, NC 28504 *(252)522-3031* www.fi eldcontrols.com...
  • Page 2: Table Of Contents

    Table of Contents Installation & Maintenance Instructions Air Purifi cation System Table of Contents Important Safety Instructions ......... . 1 Specifi...
  • Page 3: Specifi Cations

    SPECIFICATIONS Model Trio 1200: Model Trio 2000: (Capacity 1-1/2 to 3.0 tons) (Capacity 3.5 to 5.0 tons) MFG: Field Controls MFG: Field Controls Model: Trio 1200 Model: Trio 2000 Power: 120V/60 Hz .6 Amps 49.2 Watts Power: 120V/60 Hz .6 Amps 49.2 Watts...
  • Page 4: Service

    NOTE: In the event, the existing thermostat does not have the capability to operate the air-handler fan unit independently of a demand for heating or air-conditioning, it is highly recommended to install the Field Controls Healthy Home System Control PLus (HHSC+) programmable ventilation system.
  • Page 5 FIG 2 FIG 1 CHANGING THE UVC GERMICIDAL LAMPS 1. Unplug the power cord from the Trio 1200/2000 Healthy Home Purifi cation System. Unscrew the two locking knobs and remove the door. (Fig. 3) 2. Remove Photocatalytic module. (Fig. 4) 3.
  • Page 6: Tracking Fi Lter And Uv Lamp Service Time

    An optional feature of this APP can be confi g- ured to notify your HVAC contractor. Refer to Field Controls Healthy Home iAQ APP – Filter and UV Lamp Tracking instruction sheet (doc: 78010001000). This document is available on the Field Con- trols Web Site (www.FieldControls.com).
  • Page 7: Installation

    FOR REPLACEMENT OF FILTER AND UVC GERMICIDAL LAMPS Contact your local HVAC contractor INSTALLATION Make sure to install the Trio 1200/2000 Healthy Home Purifi cation System so that the inlet or return air enters the side containing the MERV13 particulate reduction cartridge fi rst. 1.
  • Page 8 FIG 8 FIG 9 5. Seal all seams with an approved air duct sealant between the air handler and the outlet side of the Trio1200/2000 so that there can be no air bypassing the system. 6. Attach the air handler to the outlet side of the Trio 1200/2000 and fasten with #10 x 3/8 self-drilling sheet metal screws.
  • Page 9 Designed in accordance with UL 1598 and CAN/CSA C22.2 page 9...
  • Page 10: Product Label Placement

    WIRING DIAGRAM FIG 10 - Electrical Diagram PRODUCT LABEL PLACEMENT Label is shipped in bagged parts seperately and should be placed on unit as noted below. page 10...
  • Page 11 * Denotes transformer installed on product shipped prior to 2016. page 11...
  • Page 12: Warranty

    WARRANTY For warranty information about this or any Field Controls product, visit: www.fi eldcontrols.com Phone: 252.522.3031 • Fax: 252.522.0214 www.fieldcontrols.com © Field Controls, LLC P/N 46638700 Rev K 09/18...