UV-AIRE™ AIR PURIFYING SYSTEM
UV-C light inhibits the growth and reproduction of germs and bacteria that circulate through a homes' heating
and air conditioning system. The treatment is a safe, silent, and proven way to make your home a healthier place
to live.
ITEMS INCLUDED IN KIT:
• Twin-Tube High-Output UVC Lamp
• 24 VAC Ballast* (UL listed) with Lamp Cable connector
• Lamp Cable with connector
• FlexMount™ Articulating Bracket Assembly with Magnet (patent pending)
• Shield Assembly
• Snap-In Safety Viewport
• UV Hazard Warning Label
• Alcohol Wipe for Lamp
• Installation & Operation Manual
*50 VA Transformer required (not included), order part # 46638900 TR50VA or equivalent.
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may
cause permanent eye damage or blindness. Never operate the UV-Aire™ Air Purifying System out of the
plenum. Avoid touching the glass portion of the lamp with your hands.
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.
This device MUST be installed by a qualified agency in accordance with the manufacturer's installation instructions. The definition of
a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged
in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the
precautions required, and has complied with all the requirements of the authority having jurisdiction.
Installed By:
Model: UV-13FM, 17FM
Please retain these instructions after installation.
Phone:
www.fieldcontrols.com
Installation Date:

Advertisement

Table of Contents
loading

Summary of Contents for Field Controls FlexMountUV UV-AIRE Series

  • Page 1 UV-AIRE™ AIR PURIFYING SYSTEM Model: UV-13FM, 17FM UV-C light inhibits the growth and reproduction of germs and bacteria that circulate through a homes’ heating and air conditioning system. The treatment is a safe, silent, and proven way to make your home a healthier place to live.
  • Page 2: Indication For Use

    WARNING: Never expose eyes or skin to UVC light from any source. • Looking directly at the UVC light may cause permanent eye damage or blindness. • Never operate the UV-Aire™ Air Purifying System out of the plenum. • Designed for a closed duct system. Do not mount near a supply or a return air opening. • All duct openings in direct line of site of the UV light must be sealed with aluminum tape or equivalent sealing methods.
  • Page 3 WARNING: Before installing or servicing a humidifier, air filter, heat system, or this unit, etc., always turn all power OFF and have unit unplugged. Electrical shock can cause personal injury or death. Never expose eyes or skin to direct UVC light from any source. WARNING: To prevent water damage or electric shock, do not mount unit under a humidifier.
  • Page 4 7. Attach the Mounting Bracket Assembly to the mounting surface using the magnet. If the mounting surface is insulated, slit the insulation, insert the magnet through the slit, draw the insulation back over the magnet and bracket surface, and tape closed using metal tape or other means that would not be affected by UVC rays. Some surfaces may be inadequate for mounting with the magnet (rough, uneven, heavy paint etc.). The magnet may be removed from the Mounting Bracket Assembly, and the bracket assembly attached to the mounting surface with included sheet metal screws or other appropriate fasteners.
  • Page 5 14. Identify an area of the access panel or other area of the equipment or duct through which the lamp may be seen. Verify that the surface is free of dirt, oil, and other contaminants, peel of the label backing and apply the Safety label to the surface such that the warning information is clearly visible (see Figure 8). 15. Drill a 3/8” hole through the center of the Safety Label, where indicated by the dashed circle (see figure 7). 16. Snap the clear plastic Safety Viewport into the hole (see Figure 8). The lamp may be safely viewed through the viewport while it is lit. 17. Verify that all electrical connections are tight and that the lamp and bracket is secure. 18. Replace all access panels and other items that may have been removed during the installation, such as electrical box covers, etc.
  • Page 6: Maintenance

    CAUTION: MAKE CERTAIN THAT POWER HAS BEEN DISCONNECTED TO THE HVAC SYSTEM, AND THE 24 VAC TRANSFORMER POWER SOURCE, BEFORE PROCEEDING WITH THE INSTALLATION! 8. Follow steps 9-20 in the Magnet Mount Installation section to complete the installation (see Figures 7, 8, 9). WARNING: BEFORE RESTORING POWER TO THE HVAC SYSTEM OR THE TRANSFORMER POWER SOURCE, VERIFY THAT NO OPENINGS EXIST THROUGH WHICH UVC RAYS FROM THE LAMP MAY ESCAPE. VERIFY THAT ALL ACCESS PANELS AND DUCTWORK ETC. HAVE BEEN REPLACED AND SEALED IF NECESSARY, AND THAT THE SAFETY VIEW PORT IS SECURELY FASTENED IN PLACE.
  • Page 7: Troubleshooting Guide

    TROUBLESHOOTING GUIDE 1. If the lamp does not light up, replace the lamp. 2. If the lamp still does not light up after replacing the lamp, replace ballast. REPLACEMENT PARTS LIST MODEL LAMP P/N BALLAST P/N UV-13FM 46632513 46635900 UV-17FM 46632517 OPTIONAL ACCESSORY PARTS LIST MODEL DESCRIPTION PART NUMBER Transformer 120-208-240V Primary TR50VA 46638900 24VAC,50 VA Universal Mount WARNING: never expose eyes or skin to UVC light from any source.