H8PS
Functions
Function
Encoder rotational direction switch
Encoder origin designation
Angle display designation
Rotation display monitor
TEACH function
Monitor contents

Specifications

Part number
Supply voltage
Power consumption
Encoder
Type
input
Response
speed
Output type
Cam outputs
Number
Rating
RUN output
Number
Rating
Tachometer
Resolution
Rating
Output response time
Display type
Materials
Mounting
Memory backup
Connections
Weight
Enclosure rating
Approvals
UL
CSA
Others
Ambient
Operating
temperature
Storage
Ambient humidity
Vibration
Malfunction 10 to 55 Hz, 0.5-mm amplitude, and 55 to 150 Hz under 7 G acceleration for 32 minutes in 3 directions
resistance
Mechanical 10 to 55 Hz, 7.5 mm amplitude, and 55 to 150 Hz under 10 G acceleration for 32 minutes in 3 directions
Shock
Malfunction Approx. 20 G
resistance
Mechanical Approx. 30 G
Insulation resistance
Dielectric strength
2
Description
Encoder data revolutions can be set to clockwise or counterclockwise via dip switches.
The process display angle can be set to the origin as 0° at the press of a button.
The unit can convert the display of absolute encoder values of
256 division/revolution to 360°/revolution.
Graphic display of encoder rotational angle position.
The unit can set the ON/OFF angle from actual operation of the machine.
Process value display with 11 mm (0.43 in.) character height, output display, settings display,
set cam number display, mode display, revolution display, operation step display, and error
message display.
H8PS-8B
H8PS-8BF
24 VDC, 85% to 110% of rated voltage in operation
Approx. 4 W
Omron's E6CP and E6F absolute rotary encoders
Run mode: 330 rpm max.
Switch selectable between high speed (60 to 330 rpm) and low speed (up to 60 rpm)
Test mode: 60 rpm max.
Includes malfunction data detection function
NPN open collector transistor
8 lines (output numbers 1 to 8)
100 mA max., 30 VDC; residual voltage 2 V max.
1; Turns ON in RUN and TEST modes, OFF in Program mode in case of error
100 mA max., 30 VDC; residual voltage 2 V max.
60 pulses/revolution signal output for rpm meter
30 mA max., 30 VDC, residual voltage 0.5 V max.
RUN mode: 0.5 ms max. under high-speed designation
2.5 ms max. under low-speed designation
TEST mode: 5 ms max.
Backlit LCD
Plastic case
Panel, 1/4 DIN cutout
Surface or track
Battery, 10 years at 25°C
Screw terminals for outputs; connector socket for encoder
Approx. 300 g (10.5 oz.)
NEMA 4 with optional Y92A-96N panel cover
Recognized, File Number E41515
Certified, File Number LR22310
SEV, File Number 1021
-10° to 55°C (14° to 131°F)
-25° to 65°C (-13° to 149°F)
35 to 85% RH
100 MΩ minimum at 500 VDC between current-carrying terminal and non-current-carrying metal part
1,000 VAC, 50/60 Hz for 1 minute between current-carrying part and non-current-carrying metal part
H8PS-8BP
H8PS-8BPF
PNP open collector transistor
30 mA max., 30 VDC, residual voltage 2 V max.
Panel, 1/4 DIN cutout
Surface or track
H8PS