Troubleshooting

Power failure

Symptom

The device cannot be powered on.

Solution

To resolve the problem:
Verify that the power source is as required by the device.
1.
Verify that the power cord is connected securely.
2.
Verify that the power cord is in good condition.
3.
If the problem persists, contact H3C Support.
4.
No display or garbled display on the configuration
terminal
Symptom
The configuration terminal does not have display or have a garbled display when the device is
powered on.
Solution
To resolve the problem:
Verify that the power system is operation correctly.
1.
Verify that the console cable is connected correctly to the specified serial port on the
2.
configuration terminal.
Verify that the following settings are configured for the terminal:
3.
Baud rate—9,600.
Data bits—8.
Parity—none.
Stop bits—1.
Flow control—none.
Emulation—VT100.
Verify that the console cable is in good condition.
4.
If the problem persists, contact H3C Support.
5.