Fig 3-5 Test Mode Operation Flow-Chart - Prodigit 3302F Mainframe Operation Manual

Table of Contents

Advertisement

22 PRODIGIT
Example 2:
Once the edit mode has been used to set the 16 step auto-sequence the user
Can press the TEST key. If the test fails at one of the test steps the LCD will flash
"NG" and the test will stop. The user can then press ENTER key to continue the
Test or press the EXIT button to leave the test mode.
Exit
Normal Mode
Show NG
Stop
4
Enter/Exit?
4.2
Exit
Normal Mode
Show PASS
TEST MODE
Show Fx
Initial = F1
ENTER
START TEST
1
Testing(T1)
2
Yes
3
NG ?
No
Step = Step+1
Delay(T2)
4.1
Enter
5
No
End ?
Yes
PASS
FAIL
PASS/FAIL
5.2
Show FAIL

Fig 3-5 TEST MODE OPERATION FLOW-CHART

1.Press TEST key
2.Press STATE 1~9 Select F1-F9
3.Press ENTER
1.
Recall correspond memory which had been
stored in F1-F9 memory
2.
Check the GO/NG indicator
3.
Stop testing if the result was NG.
3.1
Press ENTER to be continued.
5.1
3.2 Press EXIT to end the test,and back to normal mode.
4.If test is GO,than step is last?
4.1 If no than Step+1,continue another step
4.2 If " Yes" , than if all the test in all m odule is pass, show GO
5.3
4.3 If "Yes", thanif there is at least one failure during the
test, show NG

Hide quick links:

Advertisement

Table of Contents
loading