5.2 Example of Temperature Calibration

Port:0x0E
Description
CmdID
SetGlobal
0x01
CalibrateReq
SetGlobal
0x81
CalibrateRsp
GetGlobal
0x02
CalibrateReq
GetGlobal
0x82
CalibrateRsp
ClearGlobal
0x03
CalibrateReq
ClearGlobal
0x83
CalibrateRsp
SensorType : Temperature 0x01
(1) Temperature calibration:
If the temperature the R718CX detects is 16° and the actual temperature is 26°, it means the
calibration we want to make is +10°
SensorType =0x01, Channel 1= 0x00, Multiplier = 0x0001, Divisor =0x0001, DeltValue=0x0064
Downlink:0101000001000100640000
Response:
8101000000000000000000 (Configuration success)
8101000100000000000000 (Configuration failure)
(4) Check whether the temperature calibration
Downlink:0201000000000000000000
Response:8201000001000100640000(Current configuration)
SensorType
Channel(1Byte)
0_Channel1,
1_Channel2,etc
Channel(1Byte)
0_Channel1,
1_Channel2,etc
0x01
(1Byte,0_Channel1,1_Channel2,etc)
Channel(1Byte)
0_Channel1,
1_Channel2,etc
Status
(1Byte,0x00_success)
PayLoad (Fix =9 Bytes)
Multiplier
Divisor
(2bytes,
(2bytes,
Unsigned)
Unsigned)
Status
(1Byte,0x00_success)
Channel
Multiplier
Divisor
(2bytes,
(2bytes,
Unsigned)
Unsigned)
Reserved
(10Bytes,Fixed 0x00)
8
Reserved
DeltValue
(2Bytes,Fixed
(2bytes,Signed)
0x00)
Reserved
(7Bytes,Fixed 0x00)
Reserved
(8Bytes,Fixed 0x00)
Reserved
DeltValue
(2Bytes,Fixed
(2bytes,Signed)
0x00)
Reserved
(9Bytes,Fixed 0x00)

Advertisement

Table of Contents
loading

This manual is also suitable for:

R718ckR718cr

Table of Contents