5.1 Example of Report configuration

FPort:0x07
Bytes
1
CmdID DeviceType
CmdID– 1 byte
DeviceType– 1 byte – Device Type of Device
NetvoxPayLoadData– var bytes (Max=9bytes)
ConfigReport
Req
ConfigReport
R718CK
Rsp
R718CT
ReadConfig
R718CR
ReportReq
ReadConfig
ReportRsp
(1) Configure R718CK report parameters:
MinTime = 1min、MaxTime = 1min、BatteryChange = 0.1v、TemperatureChange = 1°C
Downlink: 0191003C003C01000A0000
Response:
(2) Read Configuration:
Downlink: 0291000000000000000000
Response:
1
MinTime
0x01
(2bytes Unit:s)
0x81
0x91
0x92
0x02
0x93
MinTime
0x82
(2bytes Unit:s)
8191000000000000000000 (Configuration success)
8191010000000000000000 (Configuration failure)
8291003C003C01000A0000 (Current configuration)
Var(Fix =9 Bytes)
NetvoxPayLoadData
MaxTime
BatteryChange
(2bytes Unit:s)
(1byte Unit:0.1v)
Status
(0x00_success)
Reserved (9Bytes,Fixed 0x00)
MaxTime
BatteryChange(1b
(2bytes Unit:s)
yte Unit:0.1v)
3C(Hex) =60(Dec)
7
Temperature
Change
(2Bytes,Fixed
(2byte
Unit:0.1°C)
Reserved (8Bytes,Fixed 0x00)
Temperature
Reserved
Change
(2Bytes,Fixed
(2byte
Unit:0.1°C)
0A(Hex) = 10(Dec)
Reserved
0x00)
0x00)