6. Installation

1. The Wireless Thermocouple Sensor (R718CK/T/R)
has a built-in magnet (see Figure 1 below). When
installed, it can be attached to the surface of an object
with iron which is convenient and quick.
To make the installation more secure, use screws
(purchased) to secure the unit to a wall or other surface
(see Figure 2 below).
Note:
Do not install the device in a metal shielded box or in an
environment with other electrical equipment around it to
avoid affecting the wireless transmission of the device.
Note:
Please do not disassemble the device unless it is required to replace the batteries.
Do not touch the waterproof gasket, LED indicator light, function keys when replacing the batteries.
Please use suitable screwdriver to tighten the screws (if using an electric screwdriver, it is
recommended to set the torque as 4kgf) to ensure the device is impermeable.
2. When R718CK/T/R is compared with the
last reported values, the temperature change
is exceeded 10°C (default),it will report
values at the MinTime interval;
If does not exceeded 10°C (default) ,it will
report values at the MaxTime interval;
R718CK/T/R is suitable below scenarios:
⚫Oven
⚫Industrial control equipment
⚫Semiconductor industry
11