8. Cleaning and Maintenance

The HTRS230V(30) thermostat requires no special maintenance. Periodically, the outer casing can be wiped clean using a dry cloth (please DO NOT use
solvents, polishes, detergents or abrasive cleaners, as these can damage the thermostat). There are no user serviceable parts within the unit; any servicing
or repairs could only be carried out by Salus Controls or their appointed agents.

9. Technical Informations

85 mm
24
Power supply
Rating max
Temperature setback
Temperature range
Span
Storage temperature
Ambient temperature
Degree of protection
CE conformity according to
Housing material
Color
Control method
Connection
Weight
Puls-wide-modulation (PWM)
Heating and Cooling
Parameter adjustment
Dimensions
85 mm
230 VAC, +/-10%, 50/60 Hz
0,5 A
Adjustable
5°C – 35°C
+/-0,5ºC or +/-0,25ºC
-20°C to +60°C
0 °C up to 45 °C
IP 30
Class II ( EN60730 )
PC, V2
RAL 9010 pure white
PWM algorithm
Hysteresis +/-0,5ºC or +/-0,25ºC
Screw terminal
125 g net / 170 g gross
Yes
Yes, automatic modes changeover
through CO terminal
Yes, in Installer Mode
85mm x 85mm x 25mm
85 mm
25 mm