6. OPTION INSTALLATION

6-1. Dallas Key (Clerk key kit CLK-K22)
1. Remove the upper cover as shown in steps 1 to 3 of page 9.
2. Fix the Dallas Cable Assy to the Dallas cover.
3. Fix the Dallas cover to the lower case by screw.
4. Let the Dallas cable through the unit and connect it to the MAIN PCB (CN25).
Note : Wind the cable through the Ferrite core two and a half times.
5. Fix the Ferrite core to the chassis by insulock tie.
6. Fix the UPPER COVER.
Insulock tie
Dallas Cable Assy
iButton probe (DS9092)
N
Code No.
N
1010 4433 COVER/DALLAS E468
1008 6507 DALLAS CABLE ASSY
1007 3068 DAS-02 CABLE SUB ASSY
1007 3671 CORE/FERRITE
1007 9263 DALLAS KEY ASSY/6PCS
1007 3701 iBUTTON/CLERK
1007 3665 iBUTTON MOUNT PROD/CLERK DS9093N
Ferrite core
Screw
Dallas cover
Dallas key Assy
DS1982-F5
DS9093N
Parts Name
Specification Q'ty Price
RJE500428-1
E441328*1
E441319-1
TR-20-10-10
RJE500025*1
DS1982-F5
— 34 —
CN25
Das 02 Sub Assy
Note
Code
1
This part is attached in the carton box of
TE-7000S/8000F/8500F.
1
CD
Clerk key kit (CLK-K22)
1
AB
Wire with connector( t = 40mm )
1
AD
Clerk key kit (CLK-K22)
1
DA
Clerk key kit (CLK-K22)
1
BF
1
AO