1. SPECIFICATIONS 1-1. Electrical specifications 120 V 220 V 230 V 240 V • Power consumption In operation Max. 0.22 A 0.13 A 0.13 A 0.13 A • Memory protection Back-up battery Mangan Battery (UM-3 3 pcs) Back-up period 1 year (25 C) Battery life Replace the battery every 1 years.
Page 4
1-4. Drawer List DRAWER NAME Specification NOTE • DL-1329 (S type) D-21G2M-D54RM-16 U.S.A • DL-1841 (S type) D-21G2M-CD53RM-16 Germany, Europe, Other countries • DL-2794 (M type) D-18G2C-A84RM-13 Europe, Other countries • DL-2796 (M type) D-18G2C-A84RM-13 UK/Canada 1-5. Option List DEVICE NAME MODEL NOTE •...
2. MACHINE INTIALIZATION 2-1. Initialization and loading memory protection battery Note: You must initialize the cash register and install the memory protection batteries before you can program the cash register. To initialize the cash register 1. Set the mode switch to OFF. 2.
3. BLOCK DIAGRAM 7 seg LED*8digits Rear display : E270-E2-2 Main display : E270-E2-1 7 seg LED*8digits +14 seg LED*1digit Mode SW Winder motor Batt Power E270-1 Drower E271-PR Printer Key FPC POWER AC Adapter DC6V/2A — 4 —...
4. DISASSEMBLY Removing the register 1. Remove the journal cover and then the WINDING PULLY. 2. Remove the battery cover and then the battery. 3. Remove the two screws. Screws 4. Separate the main unit as shown below. — 5 —...
Page 8
5. Remove the connector (CN7) as well as the power jack, and then separate the main unit from the drawer. Removing the main PCB 6. Remove the connectors (CN6, CN8), FPCs(CN1, CN3, CN9) and the two screws and then remove the main PCB. Screws Disassembling the keyboard unit 7.
Page 9
Removing the switch PCB (E270-PR) 9. Remove the two screws. Lift up the PCB and remove the FPC and then the PCB. Disassembling the display unit 10. Remove the display cover. Hooks 3 Hooks 1 Hooks 4 Hooks 2 (1) Open the printer cover and remove Hook1 and Hook2. (2) Remove Hook3 and Hook4.
Page 10
12. Remove the LCD board. Hooks Hooks Removing the key unit 13. Removing one screw and then the key unit. Screw Removing the printer unit 14. Remove the three screws and then the printer unit. Screws — 8 —...
Page 11
Disassembling the drawer (DL-1329/DL-1841) 15. Remove one screw and then the power unit. Screw Hooks 16. Pull the lever and remove the tray. 17. Remove the three screws and then the top plate. 18. Remove the three screws and the solenoid. Screws —...
Page 14
5-1-3. Pin Function PIN NO. PIN NAME DESCRIPTION P120/RTP0 P121/RTP1 P122/RTP2 P123/RTP3 8 bit input/output PORT P124/RTP4 P125/RTP5 P126/RTP6 P127/RTP7 Power Supply Main system Clock Sub system Clock RESET Reset P00/INTP0 P01/INTP1 P02/INTP2/NMI 7 bit input/output PORT P03/INTP3 P04/INTP4 P05/INTP5 P06/INTP6 AVDD A/D CONVERTER POWER SUPPLY...
Page 15
PIN NO. PIN NAME DESCRIPTION P83/A3 P84/A4 P85/A5 8 bit input/output PORT P86/A6 P87/A7 P40/AD0 P41/AD1 P42/AD2 P43/AD3 8 bit input/output PORT P44/AD4 P45/AD5 P46/AD6 P47/AD7 P50/A8 P51/A9 P52/A10 P53/A11 8 bit input/output PORT P54/A12 P55/A13 P56/A14 P57/A15 P60/A16 P61/A17 P62/A18 P63/A19 8 bit input/output PORT...
6. DIAGNOSTIC OPERATION To start the diagnostic program ECR enters the diagnostic mode by the following operation. 1 Turn the mode key to PGM. 2 Input “99990000” and #2 (SUB TOTAL). Upon the above operation ECR prints the following and issues a receipt. * Note that the test mode will not boot if once a receipt has been issued in the REG/RF/X/Z mode.
6-3. Displaying the Switch Condition Press the clear key, or change the status of switches to display the current conditions. [DISPLAY] Mode SW 1:PGM, 2:RF, 3:REG, 4:CAL, 5:X, 6:Z, 8:OFF, 0:no contact FEED key 1:ON, 0:OFF No display PAD2 1:SHORT 0:OPEN PAD1 1:SHORT...
6-4. Printing and Display test Bulk test Operation : #2 SUB TOTAL All lit in the display, time and date setting, drawer open, receipt issuing (only in the receipt mode) • All lit (display) : 88888888= (transaction) • Waits for key input (the test proceeds by the input of any key other than the clear key, ten keys and FEED key.) •...
Page 22
Winder test Operation : #2 SUB TOTAL The drive time of the winder motor can be changed. Default is 50msec. X:0 30 msec :1 35 msec :2 40 msec :3 45 msec :4 50 msec :5 55 msec :6 60 msec :7 65 msec :8 70 msec :9 75 msec...
7. TROUBLESHOOTING Symptom/Problem Most common causes Solutions E01 appears on the display. Changing modes without com- Return key to where it stops pleting transaction. buzzing and press CA/AMT /TEND When the printer does not print Check the platen arm/shut properly. down and close it firmly.
8. IC DATA 1. ULN2003AFW (IC1, IC2) 20 O1 COMMON 2. S-80819CNNB-B8E (IC6), S-80850CNNB-B9B (IC7) VREF Symbol Description Voltage detection output pin Voltage input pin Non-connected Ground pin *1. NC pin is electrically open. Connecting this pin to VDD or VSS is allowed. 3.
2. As for spare parts order and supply, refer to the “GUIDEBOOK for Spare Parts Supply”, published separately. 3. The numbers in item column corespond to the same numbers in drawing. 4. CASIO does not supply the spare parts without parts code. 5. Remarks Q'ty :...
PARTS PRICE LIST TE-M80 Q'ty Item Code No. Parts Name Specification Other Countries Price Europe Germany Australia Plug Type Code 1. MAIN PCB BLOCK 10131708 PCB ASSY/E270-1 RJE500763*001V01 10140512 PCB ASSY/E270-1 RJE500763*003V01 10140513 PCB ASSY/E270-1 RJE500763*004V01 N IC4 10137724 UPD784215AGC2388EU N IC4 10136098 UPD784215AGC2368EU...