ARCNET
rllmmx0a51
END
rllmmx0a51
* Error print
| ARCNET RETRY OVER
| ARCNET BLK ERR
| ARCNET DATA ERR
| ARCNET LENG ERR
| ARCNET TIMEOUT
| ARCNET OPEN ERR
[ 23 ] ARCNET batch
test
[Function]
This test will perform the ARCNET counter communication with the fixed set value.
Connect the two ECRs and perform the counter communication test.
The number of retries will be displayed in the upper right corner of the LCD.
[Operation]
* Send ECR
Operation :
1
Fixed set value
ID of the other ECR: 01, Own ID: 02
Mode selection: send mode
Baud rate: 312 kbps
The number of retries = 5
* Receive ECR
Operation :
2
Fixed set value
ID of the other ECR: 02, Own ID : 01
Mode selection: receive mode
Baud rate: 312 kbps
The number of retries = 5
[LCD]
* Send ECR
ARCNET
150
END
150
* Receive ECR
ARCNET
250
END
250
[Print]
Refer to [ 22 ] ARCNET test for the error print.
| Selected retry number was exceeded.
| Received does not correspond to the sent Block No.
| Received data does not correspond to the sent data.
| Received data length does not correspond to the sent data length.
| Time out error when starting the ECR or between blocks.
| ARCNET initialization failed.
5
0
SUBTOTAL
5
0
SUBTOTAL