Cleaning Intervals; Cleaning Prompt And Dispensing Lock; Cleaning Agents; When Using Canisters - Melitta Cafina XT4 Operating Instructions Manual

Professional coffee solutions
Hide thumbs Also See for Cafina XT4:
Table of Contents

Advertisement

8�2

Cleaning intervals

Interval
After every use
Daily
(1, 2)
Daily
Daily
Daily
1x weekly
Following an
extended standstill
As required
As required (at
least once a
month)
As required (at
least once a
month)
Twice a day for heavier use (more than 20 l of milk or more
(1)
than 150 coffee products).
Once a week an additional cleaning with AMC cleaner is
(2)
required.
8
8�3

Cleaning prompt and dispensing lock

If cleaning is required (e.g., one of the programmed
cleaning times has been exceeded), the cleaning prompt
appears on the display. Products can then only be
dispensed for a limited time or number of products.
If no cleaning work is carried out, product dispensing is
then locked. The products are no longer displayed and
cannot be dispensed.
To reset the cleaning prompt or dispensing lock, the
machine must be cleaned.
Cleaning
Which parts?
How to clean
Steam wand
Emit steam for
approx. 2 seconds.
Then clean with a
clean, damp cloth.
Milk and brewing
Start cleaning
system
program.
Instant system
Clean.
Coffee grounds
Clean.
drawer
All systems/parts
Clean with a clean,
that have been
damp cloth.
used at least once
Bottom of
Clean with a clean,
beverage outlet
damp cloth; use
and bottom of
a damp brush if
milk foam wand
necessary.
Milk and brewing
Start cleaning
system
program.
Mixer unit of
Rinse mixer unit.
instant system
Bean and instant
Clean.
containers
Housing parts
Clean externally
with a clean,
Surfaces,
damp cloth.
plastic parts,
painted
surfaces
28
8�4

Cleaning agents

Only use the cleaning agents listed as these are best
suited to the automatic cleaning program:
• Melitta® Cafina® Multi TF-Tabs (art. no. 31547)
• Melitta® Cafina® AMC cleaner (art. no. 35289)
CAUTION
Damage to health due to cleaning agents!
The components in the cleaning agents may irritate eyes
and skin, and may be harmful to health if inhaled or
swallowed.
• Keep all information about the cleaning agents easily
accessible in case of emergency.
• Always keep cleaning agents out of the reach of
children.
• Only use the cleaning agents listed in the instruc-
tions, otherwise the legal warranty will become void.
• Wear gloves when handling cleaning tablets.
• Observe warning notes on the packaging of the
cleaning agents.
• Observe the recommended usage quantity.
8�5

When using canisters

1. Empty both canisters daily.
͵ Do not leave any water residue in the canisters;
even fresh water quickly becomes contaminated.
2. Also observe the limit values for water carbonate
hardness during canister operation.
͵ Where necessary, the fresh water supply must be
topped up via a water filter (e.g., BRITA-Purity).
3. Before filling, clean the fresh water canister and its
lid area with standard dishwashing detergent and
rinse off the cleaner residues thoroughly.
4. Also clean the waste water tank daily with detergent
to prevent unpleasant odors forming due to organic
waste in the waste water.
5. At least once a month clean the suction lance with
detergent and rinse off the cleaner residues thor-
oughly.
͵ Make sure that the filter insert in the intake piece
at the bottom end of the suction lance is clean
and free.
6. Ensure that the fresh water canister is filled with
sufficient water and that the waste water canister is
empty before you start the cleaning program.