Display Warnings - Unitek BAMOCAR-D3 Manual

Digitalbattery-motor-controller for ecservomotors acinductionmotors dc-servo
Table of Contents

Advertisement

Electrical Installation
Fault –warning indications on BAMOCAR-D3
In case of „warning", the red FAULT led blinks and the 7 segment display alternatively
indicates the status and the warning number.
List
warning messages
Display at
Error message
the
on the NDrive
BAMOCAR
0
1
2
3
4
5
POWERVOLTAGE
6
MOTORTEMP
7
DEVICETEMP
8
OVERVOLTAGE
9
A
B
C
D
E
F
red FAULT led
Example:
indication toggles between status and warning number.
warning number 5 POWERVOLTAGE
power voltage too low or not present
equipment temperature > 87 %
I_PEAK
I2R
flashes,
Meaning
motor temperature > 87 %
over voltage > 1.5 x un
over current 200 %
over load > 87 %
ID-
address
0x8f
bit 16
bit 17
bit 18
bit 19
bit 20
bit 21
bit 22
bit 23
bit 24
bit 25
bit 26
bit 27
bit 28
bit 29
bit 30
bit 31
41